Abstract

Objective To prepare a novel H2O2-loaded and phase-change nanoparticles, combined with low intensity focused ultrasound (LIFU) to dissolve intravascular thrombosis for the evaluation of its value in the treatment of coronary artery thrombolysis in the patients with acute myocardial infarction (AMI). Methods H2O2-loaded and phase-change nanoparticles were prepared by membrane hydration method. 50 ml arterial blood was collected from rabbit carotid artery and made into 400 - 800 mg thrombus blocks. They were divided into four groups randomly: poly butylene succinate buffer (PBS) solution as blank control (group A), SonoVue microbubbles group (group B), PFP phase-change nanoparticles group (group C), H2O2-loaded and phase-change nanoparticles group (group D). Each group of thrombus samples were placed into the artificial blood vessels of the extracorporeal thrombolysis simulation cycle device and combined with LIFU irradiation. The weights and pathological presentations were compared before and after thrombolysis. The volume of O2in the vascular system was inspected using Dissolved Oxygen Detector (DOD) after LIFU exposure. Results The average size of H2O2-loaded nano-droplets was (456. 7 ± 31. 2)nm. Fluorescence microscopy showed that the structure of nanoparticles was stable and uniform in size. The weight loss and rates of thrombus in the four groups after thrombolysis were:group A (52.2 ± 11.5)mg, (9.7±3.5)%;group B (110.0 ± 21.9)mg, (19.4 ± 2.4)% ;group C (239.6 ± 46.3)mg, (39. 7 ±6.3)% and group D (309.8 ± 44. 8)mg, (54.2 ± 6.6)%, respectively. The weight loss and rates of thrombus in group C and D were higher than those in group A and B (all P <0.01), but there was no significant difference between group C and D (P >0.05). The DOD showed that along with the increase of H2O2concentration, O2release was rising. Conclusions H2O2/PFP nanoparticles with LIFU performs efficient thrombolysis and provides O2to improve hypoxia, which provides a potential novel treatment method for AMI patients with coronary embolism.

Translated title of the contributionH2O2/PFP-loaded acoustic phase-change lipid nanoparticles enhancing thrombolysis in artificial vessel for simulation of coronary circulation:an in-vitro study by low intensity focused ultrasound irradiation
Original languageChinese (Traditional)
Pages (from-to)71-76
Number of pages6
JournalChinese Journal of Ultrasonography
Volume28
Issue number1
DOIs
StatePublished - Jan 2019
Externally publishedYes

Keywords

  • Hydrogen peroxide
  • Microbubbles
  • Thrombolytic therapy
  • Ultrasonography

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'H2O2/PFP-loaded acoustic phase-change lipid nanoparticles enhancing thrombolysis in artificial vessel for simulation of coronary circulation:an in-vitro study by low intensity focused ultrasound irradiation'. Together they form a unique fingerprint.

Cite this