Anatomic change over the course of treatment for non-small cell lung cancer patients and its impact on intensity-modulated radiation therapy and passive-scattering proton therapy deliveries

Mei Chen, Jinzhong Yang, Zhongxing Liao, Jiayi Chen, Cheng Xu, Xiaodong He, Xiaodong Zhang, Ronald X. Zhu, Heng Li

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Purpose: To quantify tumor anatomic change of non-small cell lung cancer (NSCLC) patients given passive-scattering proton therapy (PSPT) and intensity-modulated radiation therapy (IMRT) through 6-7 weeks of treatment, and analyze the correlation between anatomic change and the need to adopt adaptive radiotherapy (ART). Materials and methods: Weekly 4D CT sets of 32 patients (8/8 IMRT with/without ART, 8/8 PSPT with/without ART) acquired during treatment, were registered to the planning CT using an in-house developed deformable registration algorithm. The anatomic change was quantified as the mean variation of the region of interest (ROI) relative to the planning CT by averaging the magnitude of deformation vectors of all voxels within the ROI contour. Mean variations of GTV and CTV were compared between subgroups classified by ART status and treatment modality using the independent t-test. Logistic regression analysis was performed to clarify the effect of anatomic change on the probability of ART adoption. Results: There was no significant difference (p = 0.679) for the time-averaged mean CTV variations from the planning CT between IMRT (7.61 ± 2.80 mm) and PSPT (7.21 ± 2.67 mm) patients. However, a significant difference (p = 0.001) was observed between ART (8.93 ± 2.19 mm) and non-ART (5.90 ± 2.33 mm) patients, when treatment modality was not considered. Mean CTV variation from the planning CT in all patients increases significantly (p < 0.001), with a changing rate of 1.77 mm per week. Findings for the GTV change was similar. The logistic regression model correctly predicted 71.9% of cases in ART adoption. The correlation is stronger in the PSPT group with a pseudo R2 value of 0.782, compared to that in the IMRT group (pseudo R2 = 0.182). Conclusion: The magnitude of target volume variation over time could be greater than the usual treatment margin. Mean target volume variation from the planning position can be used to identify lung cancer patients that may need ART.

Original languageEnglish (US)
Article number55
JournalRadiation Oncology
Volume15
Issue number1
DOIs
StatePublished - Mar 5 2020

Keywords

  • Adaptive therapy
  • Anatomic change
  • Proton therapy

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Anatomic change over the course of treatment for non-small cell lung cancer patients and its impact on intensity-modulated radiation therapy and passive-scattering proton therapy deliveries'. Together they form a unique fingerprint.

Cite this