Clinical decision tool for optimal delivery of liver stereotactic body radiation therapy: Photons versus protons

Saumil J Gandhi, Xing Liang, Xuanfeng Ding, Timothy C Zhu, Edgar Ben-Josef, John P Plastaras, James M Metz, Stefan Both, Smith Apisarnthanarax

Research output: Contribution to journalArticlepeer-review

46 Scopus citations

Abstract

PURPOSE: Stereotactic body radiation therapy (SBRT) for treatment of liver tumors is often limited by liver dose constraints. Protons offer potential for more liver sparing, but clinical situations in which protons may be superior to photons are not well described. We developed and validated a treatment decision model to determine whether liver tumors of certain sizes and locations are more suited for photon versus proton SBRT.

METHODS AND MATERIALS: Six spherical mock tumors from 1 to 6 cm in diameter were contoured on computed tomography images of 1 patient at 4 locations: dome, caudal, left medial, and central. Photon and proton plans were generated to deliver 50 Gy in 5 fractions to each tumor and optimized to deliver equivalent target coverage and maximal liver sparing. Using these plans, we developed a hypothesis-generating model to predict the optimal modality for maximal liver sparing based on tumor size and location. We then validated this model in 10 patients with liver tumors.

RESULTS: Protons spared significantly more liver than photons for dome or central tumors ≥3 cm (dome: 134 ± 21 cm(3), P = .03; central: 108 ± 4 cm(3), P = .01). Our model correctly predicted the optimal SBRT modality for all 10 patients. For patients with dome or central tumors ≥3 cm, protons significantly increased the volume of liver spared (176 ± 21 cm(3), P = .01) and decreased the mean liver dose (8.4 vs 12.2 Gy, P = .01) while offering no significant advantage for tumors <3 cm at any location or for caudal and left medial tumors of any size.

CONCLUSIONS: When feasible, protons should be considered as the radiation modality of choice for dome and central tumors >3 cm to allow maximal liver sparing and potentially reduce radiation toxicity. Protons should also be considered for any tumor >5 cm if photon plans fail to achieve adequate coverage or exceed the mean liver threshold.

Original languageEnglish (US)
Pages (from-to)209-18
Number of pages10
JournalPractical Radiation Oncology
Volume5
Issue number4
DOIs
StatePublished - Feb 24 2015
Externally publishedYes

Keywords

  • Computer Simulation
  • Humans
  • Liver
  • Liver Neoplasms
  • Models, Theoretical
  • Organ Sparing Treatments
  • Photons
  • Protons
  • Radiosurgery
  • Radiotherapy Planning, Computer-Assisted
  • Tomography, X-Ray Computed
  • Journal Article

Fingerprint

Dive into the research topics of 'Clinical decision tool for optimal delivery of liver stereotactic body radiation therapy: Photons versus protons'. Together they form a unique fingerprint.

Cite this