TY - JOUR
T1 - Clinical impact of strain histogram EUS elastography and contrast-enhanced EUS for the differential diagnosis of focal pancreatic masses
T2 - A prospective multicentric study
AU - Costache, Mǎdǎlin Ionut
AU - Cazacu, Irina M.
AU - Dietrich, Christoph F.
AU - Petrone, Maria Chiara
AU - Arcidiacono, Paolo Giorgio
AU - Giovannini, Marc
AU - Bories, Erwan
AU - Garcia, Julio Iglesias
AU - Siyu, Sun
AU - Santo, Erwin Florina
AU - Popescu, Carmen
AU - Constantin, Alina
AU - Bhutani, Manoop S.
AU - Saftoiu, Adrian
N1 - Publisher Copyright:
© 2020 SPRING MEDIA PUBLISHING CO. LTD | PUBLISHED BY WOLTERS KLUWER - MEDKNOW.
PY - 2020/3/1
Y1 - 2020/3/1
N2 - Background: Recent advances in EUS techniques (real-time EUS elastography and contrast-enhanced EUS) have allowed a better characterization of focal pancreatic masses. Mean strain histograms (SHs) are considered a good parameter for the semi-quantitative evaluation of focal pancreatic masses, alongside complementary contrast-enhanced EUS parameters which can be quantified during both the early arterial and late venous phase. Materials and Methods: The study design was prospective, blinded, and multicentric, assessing real-time EUS elastography and contrast-enhanced EUS results for the characterization of focal pancreatic masses using parametric measurements, in comparison with pathology which is the gold standard. SHs were performed based on the embedded software of the ultrasound system, with the values being reversed as opposed to our initially published data on hue histograms. Consequently, a cutoff of 80 was derived from previous multicentric trials. Contrast-enhanced EUS also allowed the focal masses to be classified as hyper-, iso-, or hypoenhanced in comparison with the normal pancreatic parenchyma. EUS-FNA was then performed for all patients, with a positive cytological diagnosis taken as a final proof of malignancy for the pancreatic masses. The diagnoses obtained by EUS-FNA were verified further either by surgery or during a clinical follow-up of at least 6 months. Results: A total number of 97 consecutive patients with focal pancreatic masses were included in the study. Based on previously defined cutoffs of 80, the values of sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the mean SHs for the diagnosis of pancreatic cancer were 100%, 29.63%, 78.65%, 100%, and 80.41%, respectively. Corresponding values for contrast-enhanced EUS (taking into consideration hypoenhencement as a predictive factor of malignancy) were 98.57%, 77.78%, 92%, 95.45%, and 92.78%, respectively. Combining contrast enhancement-EUS (hypoenhencement) and semi-quantitative EUS elastography (SH cutoffs <80), the resulting values corresponding for sensitivity, specificity, and accuracy were 98.57%, 81.48%, and 93.81%, respectively. Conclusion: The current study using objective parametric tools for both EUS elastography and contrast-enhanced EUS confirmed the results of previous studies and meta-analyses that indicated a complementary role for the differential diagnosis of focal pancreatic masses. Moreover, the best values for the receiver operating curves were obtained using a sequential clinical algorithm based on the initial use of elastography, followed by contrast enhancement.
AB - Background: Recent advances in EUS techniques (real-time EUS elastography and contrast-enhanced EUS) have allowed a better characterization of focal pancreatic masses. Mean strain histograms (SHs) are considered a good parameter for the semi-quantitative evaluation of focal pancreatic masses, alongside complementary contrast-enhanced EUS parameters which can be quantified during both the early arterial and late venous phase. Materials and Methods: The study design was prospective, blinded, and multicentric, assessing real-time EUS elastography and contrast-enhanced EUS results for the characterization of focal pancreatic masses using parametric measurements, in comparison with pathology which is the gold standard. SHs were performed based on the embedded software of the ultrasound system, with the values being reversed as opposed to our initially published data on hue histograms. Consequently, a cutoff of 80 was derived from previous multicentric trials. Contrast-enhanced EUS also allowed the focal masses to be classified as hyper-, iso-, or hypoenhanced in comparison with the normal pancreatic parenchyma. EUS-FNA was then performed for all patients, with a positive cytological diagnosis taken as a final proof of malignancy for the pancreatic masses. The diagnoses obtained by EUS-FNA were verified further either by surgery or during a clinical follow-up of at least 6 months. Results: A total number of 97 consecutive patients with focal pancreatic masses were included in the study. Based on previously defined cutoffs of 80, the values of sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the mean SHs for the diagnosis of pancreatic cancer were 100%, 29.63%, 78.65%, 100%, and 80.41%, respectively. Corresponding values for contrast-enhanced EUS (taking into consideration hypoenhencement as a predictive factor of malignancy) were 98.57%, 77.78%, 92%, 95.45%, and 92.78%, respectively. Combining contrast enhancement-EUS (hypoenhencement) and semi-quantitative EUS elastography (SH cutoffs <80), the resulting values corresponding for sensitivity, specificity, and accuracy were 98.57%, 81.48%, and 93.81%, respectively. Conclusion: The current study using objective parametric tools for both EUS elastography and contrast-enhanced EUS confirmed the results of previous studies and meta-analyses that indicated a complementary role for the differential diagnosis of focal pancreatic masses. Moreover, the best values for the receiver operating curves were obtained using a sequential clinical algorithm based on the initial use of elastography, followed by contrast enhancement.
KW - Chronic pseudotumoral pancreatitis
KW - EUS
KW - contrast-enhanced harmonic imaging
KW - pancreatic adenocarcinoma
KW - pancreatic neuroendocrine tumors
KW - strain histogram elastography
UR - http://www.scopus.com/inward/record.url?scp=85084203582&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85084203582&partnerID=8YFLogxK
U2 - 10.4103/eus.eus_69_19
DO - 10.4103/eus.eus_69_19
M3 - Article
C2 - 32295969
AN - SCOPUS:85084203582
SN - 2303-9027
VL - 9
SP - 116
EP - 121
JO - Endoscopic Ultrasound
JF - Endoscopic Ultrasound
IS - 2
ER -