Dosimetric Quality of Online Adapted Pancreatic Cancer Treatment Plans on an MRI-Guided Radiation Therapy System

Phillip E. Chow, Fang I. Chu, Nzhde Agazaryan, Minsong Cao, Margeurite Tyran, Yingli Yang, Daniel Low, Ann Raldow, Percy Lee, Michael Steinberg, James M. Lamb

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

Purpose: Stereotactic magnetic resonance image–guided adaptive radiation therapy (SMART) is an emerging technique that shows promise in the treatment of pancreatic cancer and other abdominopelvic malignancies. However, it is unknown whether the time-limited nature of on-table adaptive planning may result in dosimetrically suboptimal plans. The purpose of this study was to quantitatively address that question through systemic retrospective replanning of treated on-table adaptive pancreatic cancer cases. Methods and Materials: Of 74 consecutive adapted fractions, 30 were retrospectively replanned based on deficiencies in planning target volume (PTV) and gross tumor volume (GTV) coverage or doses to organs-at-risk (OARs) that exceeded ideal constraints. Retrospective plans were created by adjusting dose-volume objectives in an iterative fashion until deemed optimized. The goal of replanning was to improve PTV/GTV coverage while keeping the dose to gastrointestinal OARs the same or lower or to reduce OAR doses while keeping PTV coverage the same or higher. The global maximum dose was required to be maintained within 2% of that of the treated adaptive plan to eliminate it as a confounding factor. A threshold of 5% improvement in PTV coverage or 5% decrease in OAR dose was used to define a clinically significant improvement. Results: Of the 30 replans, 7 obtained at least 5% PTV coverage improvement. The average increase in PTV coverage for these plans was 11%. No plans were clinically significantly improved in terms of OAR sparing. Changes in beam-on time did not show any correlation. Statistical analysis via a linear mixed-effects model with a nested random effect suggested that both GTV and PTV coverage were improved over SMART process plans by 0.91 cc (P =.02) and 2.03 cc (P <.001), respectively. Conclusions: Dosimetric plan quality of at least 10% of SMART fractions may be improved through more extensive replanning than is currently performed on-table. Further work is needed to develop an automated replanning workflow to streamline the in-depth replanning process to better fit into an on-table adaptive workflow.

Original languageEnglish (US)
Article number100682
JournalAdvances in Radiation Oncology
Volume6
Issue number3
DOIs
StatePublished - May 1 2021
Externally publishedYes

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Dosimetric Quality of Online Adapted Pancreatic Cancer Treatment Plans on an MRI-Guided Radiation Therapy System'. Together they form a unique fingerprint.

Cite this