Incremental Application of Positive End-Expiratory Pressure for the Evaluation of Atelectasis during RP-EBUS and Bronchoscopy (I-APPEAR)

Grant D. Senyei, Ala Eddin S. Sagar, Brian Tran, Archan Shah, Russell Miller, Niral Patel, Keriann Van Nostrand, Roberto F. Casal, George Z. Cheng

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Background: CT-to-body divergence - described as the difference between preprocedural CT scans and intraprocedural lung architecture - is a significant barrier to improving diagnostic yield during navigational bronchoscopy. A major proposed contributor to CT-to-body divergence is the development of atelectasis, which can confound visualization of peripheral lung lesions via radial probe endobronchial ultrasound (RP-EBUS). High positive end-expiratory pressure (PEEP) ventilatory strategies have been used to decrease atelectasis, allowing the lesion to re-APPEAR on intraprocedure imaging. However, standardized PEEP levels may not be appropriate for all patients due to hemodynamic and ventilatory impacts. Methods: We performed a multicenter, prospective observational study in which patients were imaged with RP-EBUS under general anesthesia to determine if subsegmental atelectasis would resolve as incremental increases in PEEP were applied. Resolution of atelectasis was based on the transition from a non-aerated pattern to an aerated appearance on RP-EBUS. RP-EBUS images were reviewed by 3 experienced operators to determine correlation. Results: Forty-three patients underwent RP-EBUS examination following navigational bronchoscopy. Thirty-seven patients underwent incremental PEEP application and subsequent RP-EBUS imaging. Atelectasis was determined to have resolved in 33 patients (88.2%) following increased PEEP. The intraclass correlation coefficient between reviewers was 0.76. A recruitment maneuver was performed in 7 (16.3%) patients after atelectasis persisted at maximal PEEP. Atelectasis was not identified in the examined subsegments in 6 (10.8%) patients despite zero PEEP. Conclusion: RP-EBUS is an effective tool to monitor what pressure atelectasis within a lung segment has resolved with increasing levels of PEEP.

Original languageEnglish (US)
Article numbere0969
JournalJournal of Bronchology and Interventional Pulmonology
Volume31
Issue number3
DOIs
StatePublished - Jun 19 2024

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine

Fingerprint

Dive into the research topics of 'Incremental Application of Positive End-Expiratory Pressure for the Evaluation of Atelectasis during RP-EBUS and Bronchoscopy (I-APPEAR)'. Together they form a unique fingerprint.

Cite this