Skip to main navigation Skip to search Skip to main content

Inter-observer Variability of Prostate Delineation on Cone Beam Computerised Tomography Images

Research output: Contribution to journalArticlepeer-review

Abstract

Aim: To determine the inter-observer variability of defining the prostate gland on cone beam computerised tomography images for the purposes of image-guided radiotherapy. Materials and methods: Five genitourinary oncologists contoured the prostate gland on five cone beam computerised tomography datasets. The variations in prostate boundary delineation and consequent isocentre placement between observers were measured. Variations in volume and centre of mass were calculated. The variation in boundary definition was determined with finite element modelling. Results: The average standard deviation for centre of mass displacements was small, measuring 0.7, 1.8 and 2.8 mm in the left-right, anterior-posterior and superior-inferior directions, respectively. The standard deviation for volume determination was 8.93 cm3 with large variability (3.98-19.00 cm3). The mean difference between the computerised tomography-derived volume and the mean cone beam-derived volume was 16% (range 0-23.7%). The mean standard deviations for left-right, anterior-posterior and superior-inferior boundary displacements were, respectively, 1.8, 2.1 and 3.6 mm. The maximum deviation seen was 9.7 mm in the superior direction. Conclusion: Expert observers had difficulty agreeing upon the location of the prostate peri-prostatic interface on the images provided. The effect on the centre of mass determination was small, and inter-observer variability for prostate detection on cone beam computerised tomography images is not prohibitive to the use of soft tissue guidance protocols. Potential exists for significant systematic matching errors, and points to the need for rigorous therapist image recognition training and development of guidance protocols before clinical implementation of soft tissue cone beam image guidance.

Original languageEnglish (US)
Pages (from-to)32-38
Number of pages7
JournalClinical Oncology
Volume21
Issue number1
DOIs
StatePublished - Feb 2009
Externally publishedYes

Keywords

  • Cone beam computerised tomography
  • image guidance
  • image recognition
  • organ delineation
  • prostate radiotherapy

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Inter-observer Variability of Prostate Delineation on Cone Beam Computerised Tomography Images'. Together they form a unique fingerprint.

Cite this