Skip to main navigation Skip to search Skip to main content

Localization of pulmonary nodules using navigation bronchoscope and a near-infrared fluorescence thoracoscope

  • Takashi Anayama
  • , Jimmy Qiu
  • , Harley Chan
  • , Takahiro Nakajima
  • , Robert Weersink
  • , Michael Daly
  • , Judy McConnell
  • , Thomas Waddell
  • , Shaf Keshavjee
  • , David Jaffray
  • , Jonathan C. Irish
  • , Kentaro Hirohashi
  • , Hironobu Wada
  • , Kazumasa Orihashi
  • , Kazuhiro Yasufuku

Research output: Contribution to journal › Article › peer-review

Abstract

Background Video-assisted thoracoscopic wedge resection of multiple small, non-visible, and nonpalpable pulmonary nodules is a clinical challenge. We propose an ultra-minimally invasive technique for localization of pulmonary nodules using the electromagnetic navigation bronchoscope (ENB)-guided transbronchial indocyanine green (ICG) injection and intraoperative fluorescence detection with a near-infrared (NIR) fluorescence thoracoscope. Methods Fluorescence properties of ICG topically injected into the lung parenchyma were determined using a resected porcine lung. The combination of ENB-guided ICG injection and NIR fluorescence detection was tested using a live porcine model. An electromagnetic sensor integrated flexible bronchoscope was geometrically registered to the three-dimensional chest computed tomographic image data by way of a real-time electromagnetic tracking system. The ICG mixed with iopamidol was injected into the pulmonary nodules by ENB guidance; ICG fluorescence was visualized by a near-infrared (NIR) thoracoscope. Results The ICG existing under 24-mm depth of inflated lung was detectable by the NIR fluorescence thoracoscope. The size of the fluorescence spot made by 0.1 mL of ICG was 10.4 ± 2.2 mm. An ICG or iopamidol spot remained at the injected point of the lung for more than 6 hours in vivo. The ICG fluorescence spot injected into the pulmonary nodule with ENB guidance was identified at the pulmonary nodule with the NIR thoracoscope. Conclusions The ENB-guided transbronchial ICG injection and intraoperative NIR thoracoscopic detection is a feasible method to localize multiple pulmonary nodules.

Original languageEnglish (US)
Pages (from-to)224-230
Number of pages7
JournalAnnals of Thoracic Surgery
Volume99
Issue number1
DOIs
StatePublished - Jan 1 2015
Externally publishedYes

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Localization of pulmonary nodules using navigation bronchoscope and a near-infrared fluorescence thoracoscope'. Together they form a unique fingerprint.

Cite this