Monte Carlo simulation of pixelated CZT detector with Geant4: Validation of clinical molecular breast imaging system

Benjamin P. Lopez, Fada Guan, Gaiane M. Rauch, S. Cheenu Kappadath

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

Purpose. Molecular breast imaging (MBI) of 99mTc-sestamibi with dual-headed, pixelated, cadmium-zinc-Telluride (CZT) detectors is increasingly used in breast cancer care for screening/detecting lesions, monitoring response to therapy, and predicting risk of cancer. MBI as a truly quantitative tool in these applications, however, is limited due the lack of absolute 99mTc-sestamibi uptake quantification. To help advance the field of quantitative MBI, we have developed a Monte Carlo simulation application of the GE Discovery NM 750b system. Methods. Our simulation consists of a two-step process using the Geant4 toolkit to model the detector and source geometry and to track photon interactions and a MATLAB script to model the charge transport within the pixelated CZT detector. Simulated detector and detector response model parameters were selected to match measured and simulated standard performance characteristics using various 99mTc point-, line-, and film-sources in air. The final model parameters were verified by comparing the count profiles, energy spectra, and region of interest counts between simulated and measured images of a breast phantom with two spherical lesions in 5 cm thick medium of air or water. Results. Final performance characteristics with 99mTc sources in air were: (1) energy resolution: 6.1% measured versus 5.9% simulated photopeak full-width at half-maximum (FWHM), (2) spatial resolution: mean error between measured and simulated FWHM of 0.08 mm across 4.4-14.0 mm FWHM range, and (3) sensitivity: 572 cpm/μCi measured versus 567 cpm/μCi simulated (<1% error). Good agreement was observed in the breast phantom line profiles through the spherical lesions and overall energy spectra, with <5% difference in sphere counts between simulated and measured data. Conclusion. A pixelated CZT charge transport and induction model was successfully implemented and validated to simulate imaging with the GE Discovery NM 750b system. This work will enable investigations improving MBI image quality and developing algorithms for uptake quantification.

Original languageEnglish (US)
Article number125009
JournalPhysics in medicine and biology
Volume66
Issue number12
DOIs
StatePublished - Jun 21 2021

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Monte Carlo simulation of pixelated CZT detector with Geant4: Validation of clinical molecular breast imaging system'. Together they form a unique fingerprint.

Cite this