Prostate cancer: Value of multiparametric MR imaging at 3 T for detection - Histopathologic correlation

Baris Turkbey, Peter A. Pinto, Haresh Mani, Marcelino Bernardo, Yuxi Pang, Yolanda L. McKinney, Kiranpreet Khurana, Gregory C. Ravizzini, Paul S. Albert, Maria J. Merino, Peter L. Choyke

Research output: Contribution to journalArticlepeer-review

401 Scopus citations

Abstract

Purpose: To determine utility of multiparametric imaging performed at 3 T for detection of prostate cancer by using T2-weighted magnetic resonance (MR) imaging, MR spectroscopy, and dynamic contrast material-enhanced MR imaging, with whole-mount pathologic findings as reference standard. Materials and Methods: This prospectively designed, HIPAA-compliant, single-institution study was approved by the local institutional review board. Seventy consecutive patients (mean age, 60.4 years; mean prostate-specific antigen level, 5.47 ng/mL [5.47 μg/L]; range, 1-19.9 ng/mL [1-19.9 m g/L]) were included; informed consent was obtained from each patient. All patients had biopsy-proved prostate cancer, with a median Gleason score of 7 (range, 6-9). Images were obtained by using a combination of six-channel cardiac and endorectal coils. MR imaging and pathologic findings were evaluated independently and blinded and then correlated with histopathologic findings by using side-by-side comparison. Analyses were conducted with a raw stringent approach and an alternative neighboring method, which accounted for surgical deformation, shrinkage, and nonuniform slicing factors in pathologic specimens. Generalized estimating equations (GEEs) were used to estimate the predictive value of region-specific, pathologically determined cancer for all three modalities. This approach accounts for the correlation among multiple regions in the same individual. Results: For T2-weighted MR imaging, sensitivity and specificity values obtained with stringent approach were 0.42 (95% confidence interval [CI]: 0.36, 0.47 ) and 0.83 (95% CI: 0.81, 0.86), and for the alternative neighboring approach, sensitivity and specificity values were 0.73 (95% CI: 0.67, 0.78) and 0.89 (95% CI: 0.85, 0.93), respectively. The combined diagnostic accuracy of T2-weighted MR imaging, dynamic contrast-enhanced MR imaging, and MR spectroscopy for peripheral zone tumors was examined by calculating their predictive value with different combinations of techniques; T2-weighted MR imaging, dynamic contrast-enhanced MR imaging, and MR spectroscopy provided significant independent and additive predictive value when GEEs were used(P < .001, P = .02, P = .002, respectively). Conclusion: Multiparametric MR imaging (T2-weighted MR imaging, MR spectroscopy, dynamic contrast-enhanced MR imaging) of the prostate at 3 T enables tumor detection, with reasonable sensitivity and specificity values.

Original languageEnglish (US)
Pages (from-to)89-99
Number of pages11
JournalRadiology
Volume255
Issue number1
DOIs
StatePublished - Apr 2010
Externally publishedYes

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Prostate cancer: Value of multiparametric MR imaging at 3 T for detection - Histopathologic correlation'. Together they form a unique fingerprint.

Cite this