Skip to main navigation Skip to search Skip to main content

Quantification of the role of lead foil in flattening filter free beam reference dosimetry

Research output: Contribution to journal › Article › peer-review

Abstract

Purpose: To quantify the potential error in outputs for flattening filter free (FFF) beams associated with use of a lead foil in beam quality determination per the addendum protocol for TG-51, we examined differences in measurements of the beam quality conversion factor kQ when using or not using lead foil. Methods: Two FFF beams, a 6 MV FFF and a 10 MV FFF, were calibrated on eight Varian TrueBeams and two Elekta Versa HD linear accelerators (linacs) according to the TG-51 addendum protocol by using Farmer ionization chambers [TN 30013 (PTW) and SNC600c (Sun Nuclear)] with traceable absorbed dose-to-water calibrations. In determining kQ, the percentage depth-dose at 10 cm [PDD(10)] was measured with 10×10 cm2 field size at 100 cm source-to-surface distance (SSD). PDD(10) values were measured either with a 1 mm lead foil positioned in the path of the beam [%dd(10)Pb] or with omission of a lead foil [%dd(10)]. The %dd(10)x values were then calculated and the kQ factors determined by using the empirical fit equation in the TG-51 addendum for the PTW 30013 chambers. A similar equation was used to calculate kQ for the SNC600c chamber, with the fitting parameters taken from a very recent Monte Carlo study. The differences in kQ factors were compared for with lead foil vs. without lead foil. Results: Differences in %dd(10)x with lead foil and with omission of lead foil were 0.9 ± 0.2% for the 6 MV FFF beam and 0.6 ± 0.1% for the 10 MV FFF beam. Differences in kQ values with lead foil and with omission of lead foil were −0.1 ± 0.02% for the 6 MV FFF and −0.1 ± 0.01% for the 10 MV FFF beams. Conclusion: With evaluation of the lead foil role in determination of the kQ factor for FFF beams. Our results suggest that the omission of lead foil introduces approximately 0.1% of error for reference dosimetry of FFF beams on both TrueBeam and Versa platforms.

Original languageEnglish (US)
Article numbere13960
JournalJournal of applied clinical medical physics
Volume24
Issue number4
DOIs
StatePublished - Apr 2023

Keywords

  • beam quality
  • flattening filter free (FFF) beams
  • lead foil
  • TG-51 addendum protocol

ASJC Scopus subject areas

  • Radiation
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Quantification of the role of lead foil in flattening filter free beam reference dosimetry'. Together they form a unique fingerprint.

Cite this