Background and purpose Diffusion-weighted imaging using echo-planar imaging (EPI) is prone to geometric inaccuracy, which may limit application to image-guided radiation therapy planning, as well as for voxel-based quantitative multi-parametric or multi-modal approaches. This research investigates pelvic applications at 3 T of a standard single-shot (ssEPI) and a prototype readout-segmented (rsEPI) technique. Materials and methods Apparent diffusion coefficient (ADC) accuracy and geometric performance of rsEPI and ssEPI were compared using phantoms, and in vivo, involving 8 patients prior to MR-guided brachytherapy for locally advanced cervical cancer, and 19 patients with prostate cancer planned for tumor-targeted radiotherapy. Global and local deviations in geometric performance were tested using Dice Similarity Coefficients (DC) and Hausdorff Distances (HD). Results In cervix patients, DC increased from 0.76 ± 0.14 to 0.91 ± 0.05 for the high risk clinical target volume, and 0.62 ± 0.26 to 0.85 ± 0.08 for the gross tumor target volume. Tumors in the peripheral zone of the prostate gland were partly projected erroneously outside of the posterior anatomic boundary of the gland by 3.1 ± 1.6 mm in 11 of 19 patients using ADC-ssEPI but not with ADC-rsEPI. Conclusions Both cervix and prostate ssEPI are prone to clinically relevant geometric distortions at 3 T. rsEPI provides improved geometric performance without post-processing.

Original languageEnglish (US)
Pages (from-to)525-531
Number of pages7
JournalRadiotherapy and Oncology
Volume117
Issue number3
DOIs
StatePublished - Dec 1 2015
Externally publishedYes

Keywords

  • Cervical cancer
  • Diffusion weighted imaging
  • Geometric distortion
  • Image-guided radiotherapy
  • MRI
  • Prostate cancer

ASJC Scopus subject areas

  • Hematology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Readout-segmented echo-planar diffusion-weighted imaging improves geometric performance for image-guided radiation therapy of pelvic tumors'. Together they form a unique fingerprint.

Cite this