Skip to main navigation Skip to search Skip to main content

Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations

Research output: Contribution to journal › Article › peer-review

Abstract

Purpose: To investigate the response of plastic scintillation detectors (PSDs) in a 6 MV photon beam of various field sizes using Monte Carlo simulations. Methods: Three PSDs were simulated: A BC-400 and a BCF-12, each attached to a plastic-core optical fiber, and a BC-400 attached to an air-core optical fiber. PSD response was calculated as the detector dose per unit water dose for field sizes ranging from 10×10 down to 0.5×0.5 cm 2 for both perpendicular and parallel orientations of the detectors to an incident beam. Similar calculations were performed for a CC01 compact chamber. The off-axis dose profiles were calculated in the 0.5×0.5 cm 2 photon beam and were compared to the dose profile calculated for the CC01 chamber and that calculated in water without any detector. The angular dependence of the PSDs' responses in a small photon beam was studied. Results: In the perpendicular orientation, the response of the BCF-12 PSD varied by only 0.5% as the field size decreased from 10×10 to 0.5×0.5 cm 2, while the response of BC-400 PSD attached to a plastic-core fiber varied by more than 3% at the smallest field size because of its longer sensitive region. In the parallel orientation, the response of both PSDs attached to a plastic-core fiber varied by less than 0.4% for the same range of field sizes. For the PSD attached to an air-core fiber, the response varied, at most, by 2% for both orientations. Conclusions: The responses of all the PSDs investigated in this work can have a variation of only 1%-2% irrespective of field size and orientation of the detector if the length of the sensitive region is not more than 2 mm long and the optical fiber stems are prevented from pointing directly to the incident source.

Original languageEnglish (US)
Pages (from-to)1596-1599
Number of pages4
JournalMedical physics
Volume38
Issue number3
DOIs
StatePublished - Mar 2011

Keywords

  • Monte Carlo simulations
  • plastic scintillation detectors
  • small-field photon beams

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations'. Together they form a unique fingerprint.

Cite this