TY - GEN
T1 - Surface-based registration of liver in ultrasound and CT
AU - Dehghan, Ehsan
AU - Lu, Kongkuo
AU - Yan, Pingkun
AU - Tahmasebi, Amir
AU - Xu, Sheng
AU - Wood, Bradford J.
AU - Abi-Jaoudeh, Nadine
AU - Venkatesan, Aradhana
AU - Kruecker, Jochen
N1 - Publisher Copyright:
© 2015 SPIE.
PY - 2015
Y1 - 2015
N2 - Ultrasound imaging is an attractive modality for real-time image-guided interventions. Fusion of US imaging with a diagnostic imaging modality such as CT shows great potential in minimally invasive applications such as liver biopsy and ablation. However, significantly different representation of liver in US and CT turns this image fusion into a challenging task, in particular if some of the CT scans may be obtained without contrast agents. The liver surface, including the diaphragm immediately adjacent to it, typically appears as a hyper-echoic region in the ultrasound image if the proper imaging window and depth setting are used. The liver surface is also well visualized in both contrast and non-contrast CT scans, thus making the diaphragm or liver surface one of the few attractive common features for registration of US and non-contrast CT. We propose a fusion method based on point-to-volume registration of liver surface segmented in CT to a processed electromagnetically (EM) tracked US volume. In this approach, first, the US image is pre-processed in order to enhance the liver surface features. In addition, non-imaging information from the EM-tracking system is used to initialize and constrain the registration process. We tested our algorithm in comparison with a manually corrected vessel-based registration method using 8 pairs of tracked US and contrast CT volumes. The registration method was able to achieve an average deviation of 12.8mm from the ground truth measured as the root mean square Euclidean distance for control points distributed throughout the US volume. Our results show that if the US image acquisition is optimized for imaging of the diaphragm, high registration success rates are achievable.
AB - Ultrasound imaging is an attractive modality for real-time image-guided interventions. Fusion of US imaging with a diagnostic imaging modality such as CT shows great potential in minimally invasive applications such as liver biopsy and ablation. However, significantly different representation of liver in US and CT turns this image fusion into a challenging task, in particular if some of the CT scans may be obtained without contrast agents. The liver surface, including the diaphragm immediately adjacent to it, typically appears as a hyper-echoic region in the ultrasound image if the proper imaging window and depth setting are used. The liver surface is also well visualized in both contrast and non-contrast CT scans, thus making the diaphragm or liver surface one of the few attractive common features for registration of US and non-contrast CT. We propose a fusion method based on point-to-volume registration of liver surface segmented in CT to a processed electromagnetically (EM) tracked US volume. In this approach, first, the US image is pre-processed in order to enhance the liver surface features. In addition, non-imaging information from the EM-tracking system is used to initialize and constrain the registration process. We tested our algorithm in comparison with a manually corrected vessel-based registration method using 8 pairs of tracked US and contrast CT volumes. The registration method was able to achieve an average deviation of 12.8mm from the ground truth measured as the root mean square Euclidean distance for control points distributed throughout the US volume. Our results show that if the US image acquisition is optimized for imaging of the diaphragm, high registration success rates are achievable.
KW - Computed tomography
KW - Electromagnetic tracking
KW - Image registration
KW - Image-guided intervention
KW - Liver-diaphragm surface
KW - Multi-modality fusion
KW - Ultrasound
UR - https://www.scopus.com/pages/publications/84943520709
UR - https://www.scopus.com/pages/publications/84943520709#tab=citedBy
U2 - 10.1117/12.2082160
DO - 10.1117/12.2082160
M3 - Conference contribution
AN - SCOPUS:84943520709
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2015
A2 - Webster, Robert J.
A2 - Yaniv, Ziv R.
PB - SPIE
T2 - Medical Imaging 2015: Image-Guided Procedures, Robotic Interventions, and Modeling
Y2 - 22 February 2015 through 24 February 2015
ER -