T1ρ-prepared balanced gradient echo for rapid 3D T1ρ MRI

  • Walter R.T. Witschey
  • , Arijitt Borthakur
  • , Mark A. Elliott
  • , Matthew Fenty
  • , Matthew A. Sochor
  • , Chenyang Wang
  • , Ravinder Reddy

Research output: Contribution to journal › Article › peer-review

Abstract

Purpose: To develop a T1ρ-prepared, balanced gradient echo (b-GRE) pulse sequence for rapid three-dimensional (3D) T1ρ relaxation mapping within the time constraints of a clinical exam (<10 minutes), examine the effect of acquisition on the measured T1ρ relaxation time and optimize 3D T1ρ pulse sequences for the knee joint and spine. Materials and Methods: A pulse sequence consisting of inversion recovery-prepared, fat saturation, T1ρ-preparation, and b-GRE image acquisition was used to obtain 3D volume coverage of the patellofemoral and tibiofemoral cartilage and lower lumbar spine. Multiple T1ρ-weighted images at various contrast times (spin-lock pulse duration [TSL]) were used to construct a T1ρ relaxation map in both phantoms and in the knee joint and spine in vivo. The transient signal decay during b-GRE image acquisition was corrected using a k-space filter. The T1ρ-prepared b-GRE sequence was compared to a standard T1ρ-prepared spin echo (SE) sequence and pulse sequence parameters were optimized numerically using the Bloch equations. Results: The b-GRE transient signal decay was found to depend on the initial T1ρ-preparation and the corresponding T1ρ map was altered by variations in the point spread function with TSL. In a two compartment phantom, the steady state response was found to elevate T1ρ from 91.4 ± 6.5 to 293.8 ± 31 and 66.9 ± 3.5 to 661 ± 207 with no change in the goodness-of-fit parameter R2. Phase encoding along the longest cartilage dimension and a transient signal decay k-space filter retained T1ρ contrast. Measurement of T1ρ using the T1ρ-prepared b-GRE sequence matches standard T1ρ-prepared SE in the medial patellar and lateral patellar cartilage compartments. T1ρ-preparedb-GRE T1ρ was found to have low interscan variability between four separate scans. Mean patellar cartilage T1ρ was elevated compared to femoral and tibial cartilage T1ρ. Conclusion: The T1ρ-prepared b-GRE acquisition rapidly and reliably accelerates T1ρ quantification of tissues offset partially by a TSL-dependent point spread function.

Original languageEnglish (US)
Pages (from-to)744-754
Number of pages11
JournalJournal of Magnetic Resonance Imaging
Volume28
Issue number3
DOIs
StatePublished - Sep 2008
Externally publishedYes

Keywords

  • Balanced steady-state free precession
  • FIESTA
  • SSFP
  • Spin-lock
  • T1rho
  • T1ρ
  • T1ρ-weighting
  • TrueFISP
  • b-SSFP

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'T1ρ-prepared balanced gradient echo for rapid 3D T1ρ MRI'. Together they form a unique fingerprint.

Cite this