Skip to main navigation Skip to search Skip to main content

The effect, of patient-to-patient variability on the accuracy of predictive assays of tumor response to radiotherapy: A theoretical evaluation

  • Susan L. Tucker
  • , Howard D. Thames

Research output: Contribution to journalArticlepeer-review

Abstract

Mathematical modeling was used to investigate the relative accuracy that might be expected from predictive assays of tumor response to radiotherapy based on one of the following four tumor characteristics: intrinsic tumor-cell radiosensitivity, doubling time of the clonogenic tumor cells, number of clonogens in the tumor at the start of treatment, and extent of hypoxia in the tumor. In particular, the influence of inter-tumor heterogeneity on predictive accuracy was investigated. Wide patient-to-patient variability in a tumor characteristic contributing to treatment response adds to the accuracy of a predictive assay based on that characteristic, but variability from patient to patient in factors influencing response, but not measured by the assay, has a confounding effect and reduces predictive accuracy. The results of this theoretical study suggest that predictive assays based on intrinsic tumor-cell radio-sensitivity are much more likely to be correlated with clinical outcome than are assays based on clonogen doubling time, hypoxic fraction, or clonogen number, since individual differences in tumor radiosensitivity can seriously confound assays based on the other factors. It is concluded that it may be necessary to correct for individual differences in Intrinsic radiosensitivity before predictive assays based on other tumor characteristics, such as potential doubling time, might have any detectable clinical significance.

Original languageEnglish (US)
Pages (from-to)145-157
Number of pages13
JournalInternational journal of radiation oncology, biology, physics
Volume17
Issue number1
DOIs
StatePublished - Jul 1989

Keywords

  • Clonogen doubling time Hypoxic fraction
  • Clonogenic tumor cells
  • Inter-tumor heterogeneity
  • Intrinsic radiosensitivity
  • Potential doubling time
  • Predictive assays

ASJC Scopus subject areas

  • Radiation
  • Oncology
  • Radiology Nuclear Medicine and imaging
  • Cancer Research

Fingerprint

Dive into the research topics of 'The effect, of patient-to-patient variability on the accuracy of predictive assays of tumor response to radiotherapy: A theoretical evaluation'. Together they form a unique fingerprint.

Cite this