TY - GEN
T1 - Tomosynthesis reconstruction from multi-beam X-ray sources
AU - Lalush, David S.
AU - Quan, Enzhuo
AU - Rajaram, Ramya
AU - Zhang, Jian
AU - Lu, Jianping
AU - Zhou, Otto
N1 - Copyright:
Copyright 2011 Elsevier B.V., All rights reserved.
PY - 2006
Y1 - 2006
N2 - We investigate methods for reconstructing tomosynthesis data using arrays of microfabricated X-ray sources and area CCD detectors. Tomosynthesis is a 3D imaging technique for limited-angle tomography that uses multiple radiographic images taken from an X-ray source placed at several positions to estimate a 3D distribution of X-ray attenuation. In our implementation, the moving X-ray source is replaced with multiple carbon nanotube field-emission X-ray sources fabricated on a single wafer. The sources are individually addressable, so the motion of the single X-ray source in traditional tomosynthesis is replaced by sequential sampling of the individual sources. Reconstruction is performed using the ordered-subsets convex (OSC) algorithm with pre-computed geometry factors and an image shearing technique for efficiency. Because of the limited resolution of tomosynthesis along the primary direction of projection, reconstructions are computed on non-cubic voxels for relatively thick slabs. We demonstrate the capabilities of the reconstruction technique on simulated data and breast phantom data from a prototype device. Reconstructions for an 11-beam system with 1000×1000 pixels per projection onto a 800×800×20 grid require 55 minutes (10 iterations) on a 3.2GHz workstation with 2 GB memory. We conclude that this implementation of the OSC algorithm is effective for reconstructing tomosynthesis datasets.
AB - We investigate methods for reconstructing tomosynthesis data using arrays of microfabricated X-ray sources and area CCD detectors. Tomosynthesis is a 3D imaging technique for limited-angle tomography that uses multiple radiographic images taken from an X-ray source placed at several positions to estimate a 3D distribution of X-ray attenuation. In our implementation, the moving X-ray source is replaced with multiple carbon nanotube field-emission X-ray sources fabricated on a single wafer. The sources are individually addressable, so the motion of the single X-ray source in traditional tomosynthesis is replaced by sequential sampling of the individual sources. Reconstruction is performed using the ordered-subsets convex (OSC) algorithm with pre-computed geometry factors and an image shearing technique for efficiency. Because of the limited resolution of tomosynthesis along the primary direction of projection, reconstructions are computed on non-cubic voxels for relatively thick slabs. We demonstrate the capabilities of the reconstruction technique on simulated data and breast phantom data from a prototype device. Reconstructions for an 11-beam system with 1000×1000 pixels per projection onto a 800×800×20 grid require 55 minutes (10 iterations) on a 3.2GHz workstation with 2 GB memory. We conclude that this implementation of the OSC algorithm is effective for reconstructing tomosynthesis datasets.
UR - https://www.scopus.com/pages/publications/33750965243
UR - https://www.scopus.com/pages/publications/33750965243#tab=citedBy
M3 - Conference contribution
AN - SCOPUS:33750965243
SN - 0780395778
SN - 9780780395770
T3 - 2006 3rd IEEE International Symposium on Biomedical Imaging: From Nano to Macro - Proceedings
SP - 1180
EP - 1183
BT - 2006 3rd IEEE International Symposium on Biomedical Imaging
T2 - 2006 3rd IEEE International Symposium on Biomedical Imaging: From Nano to Macro
Y2 - 6 April 2006 through 9 April 2006
ER -