WE‐E‐204B‐03: Feasibility of Bench‐Top Polychromatic Cone‐Beam X‐Ray Fluorescence Computed Tomography (XFCT) for In‐Phantom Detection of Gold Nanoparticles

B. L. Jones, S. H. Cho

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Purpose: To examine the feasibility of quantifying concentration and spatial distribution of gold nanoparticles (GNPs) present within a small animal‐sized object by applying an x‐ray fluorescence computed tomography (XFCT) technique with a bench‐top, polychromatic, cone‐beam x‐ray source. Method and Materials: The Monte Carlo code MCNP5 was used to simulate the acquisition of gold fluorescence photons under a polychromatic cone‐beam XFCT scenario. Three 1 cm‐diameter columns containing saline solution with GNPs (≤ 2% gold by weight) were inserted into a 5 cm‐diameter cylindrical PMMA phantom. The phantom was irradiated by a 110 kVp x‐ray source, and the resulting gold fluorescence and Compton‐scattered photons were collected by a series of 11 energy‐sensitive tallies. A maximized‐likelihood iterative reconstruction algorithm was implemented to reconstruct the image of GNP distribution. The effects of attenuation of both the primary beam through the phantom and the gold fluorescence photons en route to the detector were corrected during the image reconstruction. The attenuation map of the phantom was known a priori, although it could have been easily measured with a transmission scan. Results: An accurate image of the GNP‐containing phantom was successfully reconstructed, with both spatial distribution and relative concentration of GNPs well defined. The pixel intensity of regions containing GNPs was linearly proportional to gold concentration, which would allow XFCT technique to quantify the GNP concentration and spatial distribution of an unknown sample. Conclusion: This study shows the feasibility of performing XFCT imaging using a bench‐top, polychromatic, cone‐beam x‐ray source. The current approach would make XFCT imaging accessible to applications where a synchrotron‐based XFCT imaging may be inapplicable, such as in vivo measurements of GNP biodistribution.

Original languageEnglish (US)
Pages (from-to)3438
Number of pages1
JournalMedical physics
Volume37
Issue number6
DOIs
StatePublished - Jun 2010
Externally publishedYes

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'WE‐E‐204B‐03: Feasibility of Bench‐Top Polychromatic Cone‐Beam X‐Ray Fluorescence Computed Tomography (XFCT) for In‐Phantom Detection of Gold Nanoparticles'. Together they form a unique fingerprint.

Cite this