A new statistics-based online baseline restorer for a high count-rate fully digital system

Hongdi Li, Chao Wang, Hossain Baghaei, Yuxuan Zhang, Rocio Ramirez, Shitao Liu, Shaohui An, Wai Hoi Wong

Research output: Contribution to journalArticlepeer-review

24 Scopus citations

Abstract

The goal of this work is to develop a novel, accurate, real-time digital baseline restorer using online statistical processing for a high count-rate digital system such as positron emission tomography (PET). In high count-rate nuclear instrumentation applications, analog signals are DC-coupled for better performance. However, the detectors, pre-amplifiers and other front-end electronics would cause a signal baseline drift in a DC-coupling system, which will degrade the performance of energy resolution and positioning accuracy. Event pileups normally exist in a high-count rate system and the baseline drift will create errors in the event pileup-correction. Hence, a baseline restorer (BLR) is required in a high count-rate system to remove the DC drift ahead of the pileup correction. Many methods have been reported for BLR from classic analog methods to digital filter solutions. However a single channel BLR with analog method can only work under 500 kcps count-rate, and normally an analog front-end application-specific integrated circuits (ASIC) is required for the application involved hundreds BLR such as a PET camera. We have developed a simple statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. In this method, we acquire additional samples, excluding the real gamma pulses, from the existing free-running ADC in the digital system, and perform online statistical processing to generate a baseline value. This baseline value will be subtracted from the digitized waveform to retrieve its original pulse with zero-baseline drift. This method can self-track the baseline without a micro-controller involved. The circuit consists of two digital counter/timers, one comparator, one register and one subtraction unit. Simulation shows a single channel works at 30 Mcps count-rate with pileup condition. 336 baseline restorer circuits have been implemented into 12 field-programmable-gate-arrays (FPGA) for our new fully digital PET system.

Original languageEnglish (US)
Article number5446500
Pages (from-to)550-555
Number of pages6
JournalIEEE Transactions on Nuclear Science
Volume57
Issue number2 PART 1
DOIs
StatePublished - Apr 2010

Keywords

  • Auto-calibration
  • Baseline restoration
  • FPGA
  • Positron emission tomography (PET)

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Nuclear Energy and Engineering
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'A new statistics-based online baseline restorer for a high count-rate fully digital system'. Together they form a unique fingerprint.

Cite this