Assessment of shoulder position variation and its impact on IMRT and VMAT doses for head and neck cancer

Emily Neubauer, Lei Dong, David S. Followill, Adam S. Garden, Laurence E. Court, R. Allen White, Stephen F. Kry

Research output: Contribution to journalArticlepeer-review

29 Scopus citations

Abstract

Background: For radiotherapy of the head and neck, 5-point mask immobilization is used to stabilize the shoulders. Still, the daily position of the shoulders during treatment may be different from the position in the treatment plan despite correct isocenter setup. The purpose of this study was to determine the interfractional displacement of the shoulders relative to isocenter over the course of treatment and the associated dosimetric effect of this displacement.Methods: The extent of shoulder displacements relative to isocenter was assessed for 10 patients in 5-point thermoplastic masks using image registration and daily CT-on-rails scans. Dosimetric effects on IMRT and VMAT plans were evaluated in Pinnacle based on simulation CTs modified to represent shoulder shifts between 3 and 15 mm in the superior-inferior, anterior-posterior, and right-left directions. The impact of clinically observed shoulder shifts on the low-neck dose distributions was examined.Results: Shoulder motion was 2-5 mm in each direction on average but reached 20 mm. Superior shifts resulted in coverage loss, whereas inferior shifts increased the dose to the brachial plexus. These findings were generally consistent for both IMRT and VMAT plans. Over a course of observed shifts, the dose to 99% of the CTV decreased by up to 101 cGy, and the brachial plexus dose increased by up to 72 cGy.Conclusions: he position of the shoulder affects target coverage and critical structure dose, and may therefore be a concern during the setup of head and neck patients, particularly those with low neck primary disease.

Original languageEnglish (US)
Article number19
JournalRadiation Oncology
Volume7
Issue number1
DOIs
StatePublished - Feb 8 2012

Keywords

  • Head and neck
  • IMRT
  • Setup
  • Shoulder
  • Shoulder shifts
  • VMAT

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Assessment of shoulder position variation and its impact on IMRT and VMAT doses for head and neck cancer'. Together they form a unique fingerprint.

Cite this