Autofluorescence and diffuse reflectance spectroscopy of oral epithelial tissue using a depth-sensitive fiber-optic probe

Richard A. Schwarz, Gao Wen, Dania Daye, Michelle D. Williams, Rebecca Richards-Kortum, Ann M. Gillenwater

Research output: Contribution to journalArticlepeer-review

111 Scopus citations

Abstract

Optical spectroscopy can provide useful diagnostic information about the morphological and biochemical changes related to the progression of precancer in epithelial tissue. As precancerous lesions develop, the optical properties of both the superficial epithelium and underlying stroma are altered; measuring spectral data as a function of depth has the potential to improve diagnostic performance. We describe a clinical spectroscopy system with a depth-sensitive, ball lens coupled fiber-optic probe for noninvasive in vivo measurement of oral autofluorescence and diffuse reflectance spectra. We report results of spectroscopic measurements from oral sites in normal volunteers and in patients with neoplastic lesions of the oral mucosa; results indicate that the addition of depth selectivity can enhance the detection of optical changes associated with precancer.

Original languageEnglish (US)
Pages (from-to)825-834
Number of pages10
JournalApplied Optics
Volume47
Issue number6
DOIs
StatePublished - Feb 20 2008

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Engineering (miscellaneous)
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Autofluorescence and diffuse reflectance spectroscopy of oral epithelial tissue using a depth-sensitive fiber-optic probe'. Together they form a unique fingerprint.

Cite this