Clinical experience with cone-beam CT navigation for tumor ablation

Nadine Abi-Jaoudeh, Aradhana M. Venkatesan, William Van Der Sterren, Alessandro Radaelli, Bart Carelsen, Bradford J. Wood

Research output: Contribution to journalArticlepeer-review

27 Scopus citations

Abstract

Purpose To describe clinical use and potential benefits of cone-beam computed tomography (CT) navigation to perform image-guided percutaneous tumor ablation. Materials and Methods All ablations performed between February 2011 and February 2013 using cone-beam CT navigation were included. There were 16 patients who underwent 20 ablations for 29 lesions. Cone-beam CT ablation planning capabilities include multimodality image fusion and tumor segmentation for visualization, depiction of the predicted ablation zones for intraprocedural planning, and segmentation of the ablated area for immediate verification after treatment. Number and purpose of cone-beam CT scans were examined. The initial ablation plan, defined as number of probes and duration of energy delivery, was recorded for the 20 of the 29 lesions ablated. Technical success and local recurrences were recorded. Primary and secondary effectiveness rates were calculated. Results Image fusion was used for 16 lesions, and intraprocedural ultrasound was used for 4 lesions. Of the 20 ablations, where the ablation plans were recorded, there was no deviation from the plan in 14 ablations. In the remaining 6 ablations, iterative planning was needed for complete tumor coverage. An average of 8.7 cone-beam CT scans ± 3.2 were performed per procedure, including 1.3 ± 0.5 for tumor segmentation and planning, 1.7 ± 0.7 for probe position confirmation, and 3.9 ± 2 to ensure complete coverage. Mean follow-up time was 18.6 months ± 6.5. Ablations for 28 of 29 lesions were technically successful (96.5%). Of ablations performed with curative intent, technical effectiveness at 1 month was 25 of 26 lesions (96.1%) and 22 of 26 lesions (84.6%) at last follow-up. Local tumor progression was observed in 11.5% (3 of 26 lesions). Conclusions Cone-beam CT navigation may add information to assist and improve ablation guidance and monitoring.

Original languageEnglish (US)
Pages (from-to)214-219
Number of pages6
JournalJournal of Vascular and Interventional Radiology
Volume26
Issue number2
DOIs
StatePublished - Feb 1 2015
Externally publishedYes

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Clinical experience with cone-beam CT navigation for tumor ablation'. Together they form a unique fingerprint.

Cite this