Conspicuity of Microcalcifications on Digital Screening Mammograms Using Varying Degrees of Monitor Zooming

Tamara Miner Haygood, Elsa Arribas, Patrick C. Brennan, E. Neely Atkinson, Mark Herndon, Joseph Dieber, William Geiser, Lumarie Santiago, Chadwick M. Mills, Paul Davis, Beatriz Adrada, Selin Carkaci, Tanya W. Stephens, Gary J. Whitman

Research output: Contribution to journalArticlepeer-review

10 Scopus citations

Abstract

Rationale and Objectives: American College of Radiology guidelines suggest that digital screening mammographic images should be viewed at the full resolution at which they were acquired. This slows interpretation speed. The aim of this study was to examine the effect of various levels of zooming on the detection and conspicuity of microcalcifications. Materials and Methods: Six radiologists viewed 40 mammographic images five times in different random orders using five different levels of zooming: full resolution (100%) and 30%, 61%, 88%, and 126% of that size. Thirty-three images contained microcalcifications varying in subtlety, all associated with breast cancer. The clusters were circled. Seven images contained no malignant calcifications but also had randomly placed circles. The radiologists graded the presence or absence and visual conspicuity of any calcifications compared to calcifications in a reference image. They also counted the microcalcifications. Results: The radiologists saw the microcalcifications in 94% of the images at 30% size and in either 99% or 100% of the other tested levels of zooming. Conspicuity ratings were worst for the 30% size and fairly similar for the others. Using the 30% size, two radiologists failed to see the microcalcifications on either the craniocaudal or mediolateral oblique view taken from one patient. Interobserver agreement regarding the number of calcifications was lowest for the 30% images and second lowest for the 100% images. Conclusions: Images at 30% size should not be relied on alone for systematic scanning for microcalcifications. The other four levels of magnification all performed well enough to warrant further testing.

Original languageEnglish (US)
Pages (from-to)1509-1517
Number of pages9
JournalAcademic radiology
Volume16
Issue number12
DOIs
StatePublished - Dec 2009

Keywords

  • Digital mammography
  • microcalcifications
  • monitor zooming
  • soft-copy interpretation

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

MD Anderson CCSG core facilities

  • Biostatistics Resource Group

Fingerprint

Dive into the research topics of 'Conspicuity of Microcalcifications on Digital Screening Mammograms Using Varying Degrees of Monitor Zooming'. Together they form a unique fingerprint.

Cite this