Development and application of an elastic net logistic regression model to investigate the impact of cardiac substructure dose on radiation-induced pericardial effusion in patients with NSCLC

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Background: Typically, cardiac substructures are neither delineated nor analyzed during radiation treatment planning. Therefore, we developed a novel machine learning model to evaluate the impact of cardiac substructure dose for predicting radiation-induced pericardial effusion (PCE). Materials and methods: One-hundred and forty-one stage III NSCLC patients, who received radiation therapy in a prospective clinical trial, were included in this analysis. The impact of dose-volume histogram (DVH) metrics (mean and max dose, V5Gy[%]–V70Gy[%]) for the whole heart, left and right atrium, and left and right ventricle, on pericardial effusion toxicity (≥grade 2, CTCAE v4.0 grading) were examined. Elastic net logistic regression, using repeat cross-validation (n = 100 iterations, 75%/25% training/test set data split), was conducted with cardiac-based DVH metrics as covariates. The following model types were constructed and analyzed: (i) standard model type, which only included whole-heart DVH metrics; and (ii) a model type trained with both whole-heart and substructure DVH metrics. Model performance was analyzed on the test set using area under the curve (AUC), accuracy, calibration slope and calibration intercept. A final fitted model, based on the optimal model type, was developed from the entire study population for future comparisons. Results: Grade 2 PCE incidence was 49.6% (n = 70). Models using whole heart and substructure dose had the highest performance (median values: AUC = 0.820; calibration slope/intercept = 1.356/−0.235; accuracy = 0.743) and outperformed the standard whole-heart only model type (median values: AUC = 0.799; calibration slope/intercept = 2.456/−0.729; accuracy = 0.713). The final fitted elastic net model showed high performance in predicting PCE (median values: AUC = 0.879; calibration slope/intercept = 1.352/−0.174; accuracy = 0.801). Conclusions: We developed and evaluated elastic net regression toxicity models of radiation-induced PCE. We found the model type that included cardiac substructure dose had superior predictive performance. A final toxicity model that included cardiac substructure dose metrics was developed and reported for comparison with external datasets.

Original languageEnglish (US)
Pages (from-to)1193-1200
Number of pages8
JournalActa Oncologica
DOIs
StatePublished - 2020

ASJC Scopus subject areas

  • Hematology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Development and application of an elastic net logistic regression model to investigate the impact of cardiac substructure dose on radiation-induced pericardial effusion in patients with NSCLC'. Together they form a unique fingerprint.

Cite this