TY - JOUR
T1 - [Diagnosis value of 3.0 T diffusion-weighted imaging with background suppression magnetic resonance for metastatic lymph nodes in rectal cancer].
AU - Zhuang, Xiao zhao
AU - Yu, Shen ping
AU - Cui, J.
AU - Chen, Chuang qi
AU - Zhao, Xiao juan
AU - Pan, Bi tao
AU - Li, Zi ping
PY - 2011/11
Y1 - 2011/11
N2 - To evaluate the diagnostic value of 3.0 T diffusion-weighted imaging with background suppression (DWIBS) magnetic resonance (MR) for lymph node metastasis in rectal cancer. Thirty-five patients with rectal cancer who underwent preoperative routine MRI+DWI examination were enrolled in the study and were treated by rectal cancer resection plus lymph node dissection. Metastatic and non-metastatic lymph nodes were confirmed by postoperative pathology. Apparent diffusion coefficient (ADC) values, long-axis and short-axis diameters of lymph nodes were measured. Receiver operating characteristic (ROC) curve was used to assess the diagnostic efficacy of ADC, long-axis and short-axis diameters for differentiating metastatic lymph nodes from non-metastatic lymph nodes. A total of 151 lymph nodes were confirmed with exact location in 35 patients. Sixty-five metastatic lymph nodes and 86 non-metastatic lymph nodes were identified. The ADC values of metastatic lymph nodes and non-metastatic lymph nodes were(0.86±0.14)×10(-3) and (0.94±0.16)×10(-3) mm(2)/s respectively. The long-axis diameter were(9.78±3.13) and (7.90±1.77) mm, respectively. The short-axis diameter were (7.65±2.00) and (6.45±1.19) mm, respectively. There were statistically significant differences between metastatic and non-metastatic lymph nodes in ADC values, long-axis diameter, and short-axis diameter(all P<0.01). The areas under the ROC curve of ADC value, long-axis diameter, and short-axis diameter were 0.648, 0.706, and 0.692, respectively. Optimal cutoff values for these parameters were 1.05×10(-3) mm(2)/s, 7.95 mm, and 5.90 mm, respectively, and the corresponding sensitivities and specificities were 93.8% and 30.2%, 75.4% and 61.6%, 90.8% and 38.4%. Quantitative measurement of ADC value may reflect the degree of diffusion restriction of metastatic lymph nodes by DWIBS at 3.0 T MR. Accurate diagnosis of metastatic lymph nodes in rectal cancer demands comprehensive evaluation combining ADC value with diameter measurement.
AB - To evaluate the diagnostic value of 3.0 T diffusion-weighted imaging with background suppression (DWIBS) magnetic resonance (MR) for lymph node metastasis in rectal cancer. Thirty-five patients with rectal cancer who underwent preoperative routine MRI+DWI examination were enrolled in the study and were treated by rectal cancer resection plus lymph node dissection. Metastatic and non-metastatic lymph nodes were confirmed by postoperative pathology. Apparent diffusion coefficient (ADC) values, long-axis and short-axis diameters of lymph nodes were measured. Receiver operating characteristic (ROC) curve was used to assess the diagnostic efficacy of ADC, long-axis and short-axis diameters for differentiating metastatic lymph nodes from non-metastatic lymph nodes. A total of 151 lymph nodes were confirmed with exact location in 35 patients. Sixty-five metastatic lymph nodes and 86 non-metastatic lymph nodes were identified. The ADC values of metastatic lymph nodes and non-metastatic lymph nodes were(0.86±0.14)×10(-3) and (0.94±0.16)×10(-3) mm(2)/s respectively. The long-axis diameter were(9.78±3.13) and (7.90±1.77) mm, respectively. The short-axis diameter were (7.65±2.00) and (6.45±1.19) mm, respectively. There were statistically significant differences between metastatic and non-metastatic lymph nodes in ADC values, long-axis diameter, and short-axis diameter(all P<0.01). The areas under the ROC curve of ADC value, long-axis diameter, and short-axis diameter were 0.648, 0.706, and 0.692, respectively. Optimal cutoff values for these parameters were 1.05×10(-3) mm(2)/s, 7.95 mm, and 5.90 mm, respectively, and the corresponding sensitivities and specificities were 93.8% and 30.2%, 75.4% and 61.6%, 90.8% and 38.4%. Quantitative measurement of ADC value may reflect the degree of diffusion restriction of metastatic lymph nodes by DWIBS at 3.0 T MR. Accurate diagnosis of metastatic lymph nodes in rectal cancer demands comprehensive evaluation combining ADC value with diameter measurement.
UR - http://www.scopus.com/inward/record.url?scp=84875034782&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84875034782&partnerID=8YFLogxK
M3 - Article
C2 - 22116716
AN - SCOPUS:84875034782
SN - 1671-0274
VL - 14
SP - 842
EP - 845
JO - Zhonghua wei chang wai ke za zhi = Chinese journal of gastrointestinal surgery
JF - Zhonghua wei chang wai ke za zhi = Chinese journal of gastrointestinal surgery
IS - 11
ER -