Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer

Sandun Jayarathna, Matthew Hoang, Rajeev Badkul, Andrew Hoover

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: To determine the dosimetric impact of brachytherapy applicator displacement during intracavitary (IC) and combined intracavitary/interstitial (IC/IS) high-dose-rate brachytherapy in the treatment of cervical cancer. Material and methods: Data from 27 consecutively treated patients undergoing IC or IC/IS high-dose-rate brachytherapy with tandem and ovoid-based applicators at a single academic medical center were analyzed. Virtual applicator displacements (a single shift of whole applicator with tandem/ovoid/associated needles) of 0 (clinical position), 2, 5, 7, and 10 mm in the inferior direction were modeled on treatment planning CT or MRI scans, with maintaining the same dwell times. Radiation dose to target volumes (D90 of high-risk clinical target volume) and organs at risk (OARs) (D0.1cc, D1cc, and D2cc of bladder, rectum, and sigmoid) were calculated for each virtual applicator shift, and significance of displacements was assessed using general linear model and Kruskal-Wallis test. Results: Mean dose to high-risk clinical target volume (HR-CTV) D90 was 95.7%, 88.9%, 84.6%, and 77.1% of the prescribed dose in clinical position with displacements of 2, 5, 7, and 10 mm, respectively. Rectal D2cc significantly increased by 28% and 44% at displacement of 7 mm and 10 mm, respectively. IC/IS cases showed relatively greater dosimetric differences than IC cases, with HR-CTV D90 doses of 94.4%, 85.8%, 80.4%, and 72.4% at virtual displacements of 2, 5, 7, and 10 mm, respectively. Conclusions: Applicator displacements of 5 mm or greater result in statistically significant and clinically meaningful decreases in radiation dose to HR-CTV during 3-dimensional high-dose-rate brachytherapy treatment planning, with corresponding increase in radiation dose to the rectum. IC/IS applicator displacements lead to relatively greater differences than those of IC applicators.

Original languageEnglish (US)
Pages (from-to)334-343
Number of pages10
JournalJournal of Contemporary Brachytherapy
Volume15
Issue number5
DOIs
StatePublished - 2023
Externally publishedYes

Keywords

  • brachytherapy
  • cervical cancer
  • dosimetry
  • gynecologic cancer
  • high-dose-rate
  • interstitial
  • intracavitary

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer'. Together they form a unique fingerprint.

Cite this