Effect of fluoroscopic X-ray beam spectrum on air-kerma measurement accuracy: Implications for establishing correction coefficients on interventional fluoroscopes with KAP meters

Kevin A. Wunderle, Joseph T. Rakowski, Frank F. Dong

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

The first goal of this study was to investigate the accuracy of the displayed reference plane air kerma (Ka,r) or air kerma-area product (Pk,a) over a broad spectrum of X-ray beam qualities on clinically used interventional fluoroscopes incorporating air kerma-area product meters (KAP meters) to measure X-ray output. The second goal was to investigate the accuracy of a correction coefficient (CC) determined at a single beam quality and applied to the measured Ka,r over a broad spectrum of beam qualities. Eleven state-of-the-art interventional fluoroscopes were evaluated, consisting of eight Siemens Artis zee and Artis Q systems and three Philips Allura FD systems. A separate calibrated 60 cc ionization chamber (external chamber) was used to determine the accuracy of the KAP meter over a broad range of clinically used beam qualities. For typical adult beam qualities, applying a single CC determined at 100 kVp with copper (Cu) in the beam resulted in a deviation of < 5% due to beam quality variation. This result indicates that applying a CC determined using The American Association of Physicists in Medicine Task Group 190 protocol or a similar protocol provides very good accuracy as compared to the allowed ± 35% deviation of the KAP meter in this limited beam quality range. For interventional fluoroscopes dedicated to or routinely used to perform pediatric interventions, using a CC established with a low kVp (~ 55-60 kVp) and large amount of Cu filtration (~ 0.6-0.9 mm) may result in greater accuracy as compared to using the 100 kVp values. KAP meter responses indicate that fluoroscope vendors are likely normalizing or otherwise influencing the KAP meter output data. Although this may provide improved accuracy in some instances, there is the potential for large discrete errors to occur, and these errors may be difficult to identify.

Original languageEnglish (US)
Pages (from-to)467-474
Number of pages8
JournalJournal of applied clinical medical physics
Volume17
Issue number3
DOIs
StatePublished - 2016
Externally publishedYes

Keywords

  • Air kerma
  • DAP meter
  • Diamentor
  • Fluoroscope
  • KAP meter

ASJC Scopus subject areas

  • Radiation
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Effect of fluoroscopic X-ray beam spectrum on air-kerma measurement accuracy: Implications for establishing correction coefficients on interventional fluoroscopes with KAP meters'. Together they form a unique fingerprint.

Cite this