Initial experience of robot-assisted Ivor-Lewis esophagectomy: 61 Consecutive cases from a single Chinese institution

Y. Zhang, J. Xiang, Y. Han, M. Huang, J. Hang, A. E. Abbas, H. Li

Research output: Contribution to journalArticlepeer-review

25 Scopus citations

Abstract

This study aims to report the technical details and preliminary outcomes of robot-assisted Ivor- Lewis esophagectomy (RAILE) using two different types of intrathoracic anastomosis from a single institution in China. From May 2015 to October 2017, 61 patients diagnosed with mid-lower esophageal cancer were treated with RAILE. The RAILE procedure was performed in two stages. The first 35 patients underwent circular end-to-end stapled intrathoracic anastomosis (stapled group), and the remaining 26 patients had a double-layered, completely hand-sewn intrathoracic anastomosis (hand-sewn group). Patient characteristics, surgical techniques, postoperative complications, and pathology outcomes were analyzed. The mean operating time and mean blood loss were 315.6 ± 59.4 minutes and 189.3 ± 95.8 mL, respectively. There was one patient who underwent conversion to thoracotomy. The 30-day and in-hospital mortality rates were 0%. Overall complications were observed in 22 patients (36.1%) according to the Clavien-Dindo (CD) and the Esophagectomy Complications Consensus Group (ECCG) classifications, of whom 6 patients (9.8%) had anastomotic leakage (ECCG, Type II). The median length of hospitalization (LOH) was 10 days (IQR, 5 days). Complete (R0) resection was achieved in all cases. The mean tumor size was 3.2 ± 1.5 cm, and the mean number of totally dissected lymph nodes was 19.3 ± 9.2. Regarding the operative outcomes between stapled and hand-sewn groups, there were no significant differences in the operative time (325.4 ± 66.6 vs. 302.3 ± 45.9 min, P = 0.114), blood loss (172.9 ± 74.1 vs. 211.5 ± 117.0 mL, P = 0.147), conversion rate (2.9 vs. 0%, P = 1.000), overall complication rate (37.1 vs. 34.6%, P = 0.839) or LOH (10 vs. 9.5 days, P = 0.415). RAILE using both stapled and hand-sewn intrathoracic anastomosis is safe and technically feasible with satisfactory perioperative outcomes for the treatment of mid-lower thoracic esophageal cancer.

Original languageEnglish (US)
Article numberdoy048
JournalDiseases of the Esophagus
Volume31
Issue number12
DOIs
StatePublished - Oct 30 2018

Keywords

  • esophageal cancers
  • esophagogastric anastomosis
  • Ivor Lewis
  • robotic surgery

ASJC Scopus subject areas

  • Gastroenterology

Fingerprint

Dive into the research topics of 'Initial experience of robot-assisted Ivor-Lewis esophagectomy: 61 Consecutive cases from a single Chinese institution'. Together they form a unique fingerprint.

Cite this