Organ and effective dose reduction for region-of-interest (ROI) CBCT and fluoroscopy

Zhenyu Xiong, Sarath Vijayan, Stephen Rudin, Daniel R. Bednarek

Research output: Chapter in Book/Report/Conference proceedingConference contribution

4 Scopus citations

Abstract

In some medical-imaging procedures using CBCT and fluoroscopy, it may be needed to visualize only the center of the field-of-view with optimal quality. To reduce the dose to the patient as well as enable increased contrast in the region of interest (ROI) during CBCT and fluoroscopy procedures, a 0.7 mm thick Cu ROI attenuator with a circular aperture 12% of the FOV was used. The aim of this study was to quantify the dose-reduction benefit of ROI imaging during a typical CBCT and interventional fluoroscopy procedures in the head and torso. The Toshiba Infinix C-Arm System was modeled in BEAMnrc/EGSnrc with and without the ROI attenuator. Patient organ and effective doses were calculated in DOSXYZnrc/EGSnrc Monte-Carlo software for CBCT and interventional procedures. We first compared the entrance dose with and without the ROI attenuator on a 20 cm thick solid-water block. Then we simulated a CBCT scan and an interventional fluoroscopy procedure on the head and torso with and without an ROI attenuator. The results showed that the entrance-surface dose reduction in the solid water is about 85.7% outside the ROI opening and 10.5% in the ROI opening. The results showed a reduction in most organ doses of 45%-70% and in effective dose of 46%-66% compared to the dose in a CBCT scan and in an interventional procedure without the ROI attenuator. This work provides evidence of substantial reduction of organ and effective doses when using an ROI attenuator during CBCT and fluoroscopic procedures.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2017
Subtitle of host publicationPhysics of Medical Imaging
EditorsTaly Gilat Schmidt, Joseph Y. Lo, Thomas G. Flohr
PublisherSPIE
ISBN (Electronic)9781510607095
DOIs
StatePublished - 2017
Externally publishedYes
EventMedical Imaging 2017: Physics of Medical Imaging - Orlando, United States
Duration: Feb 13 2017Feb 16 2017

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10132
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2017: Physics of Medical Imaging
Country/TerritoryUnited States
CityOrlando
Period2/13/172/16/17

Keywords

  • CBCT
  • Dose reduction
  • EGSnrc
  • Interventional fluoroscopy procedure
  • Monte Carlo
  • ROI imaging

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Biomaterials
  • Atomic and Molecular Physics, and Optics
  • Radiology Nuclear Medicine and imaging