Parametric delineation uncertainties contouring (PDUC) modeling on CT scans of prostate cancer patients

Vi Ly, Lizhong Liu, Carlos Cardenas, Sean Maroongroge, Brian De, Daniel El Basha, Laurence Court, Xi Luo

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: Variability in contouring contributes to large variations in radiation therapy planning and treatment outcomes. The development and testing of tools to automatically detect contouring errors require a source of contours that includes well-understood and realistic errors. The purpose of this work was to develop a simulation algorithm that intentionally injects errors of varying magnitudes into clinically accepted contours and produces realistic contours with different levels of variability. Methods: We used a dataset of CT scans from 14 prostate cancer patients with clinician-drawn contours of the regions of interest (ROI) of the prostate, bladder, and rectum. Using our newly developed Parametric Delineation Uncertainties Contouring (PDUC) model, we automatically generated alternative, realistic contours. The PDUC model consists of the contrast-based DU generator and a 3D smoothing layer. The DU generator transforms contours (deformation, contraction, and/or expansion) as a function of image contrast. The generated contours undergo 3D smoothing to obtain a realistic look. After model building, the first batch of auto-generated contours was reviewed. Editing feedback from the reviews was then used in a filtering model for the auto-selection of clinically acceptable (minor-editing) DU contours. Results: Overall, C values of 5 and 50 consistently produced high proportions of minor-editing contours across all ROI compared to the other C values (0.936 (Figure presented.) 0.111 and 0.552 (Figure presented.) 0.228, respectively). The model performed best on the bladder, which had the highest proportion of minor-editing contours (0.606) of the three ROI. In addition, the classification AUC for the filtering model across all three ROI is 0.724 (Figure presented.) 0.109. Discussion: The proposed methodology and subsequent results are promising and could have a great impact on treatment planning by generating mathematically simulated alternative structures that are clinically relevant and realistic enough (i.e., similar to clinician-drawn contours) to be used in quality control of radiation therapy.

Original languageEnglish (US)
Article numbere13970
JournalJournal of applied clinical medical physics
Volume24
Issue number7
DOIs
StatePublished - Jul 2023

Keywords

  • cancer
  • contouring
  • delineation uncertainties
  • simulation algorithm
  • treatment planning

ASJC Scopus subject areas

  • Radiation
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Parametric delineation uncertainties contouring (PDUC) modeling on CT scans of prostate cancer patients'. Together they form a unique fingerprint.

Cite this