Preventive covered stent placement at the gastroduodenal artery stump in angiogram-negative sentinel hemorrhage after pancreaticoduodenectomy

Yuan Mao Lin, Ethan Yiyang Lin, Hsiuo Shan Tseng, Rheun Chuan Lee, Hsuen En Huang, Shin E. Wang, Yi Ming Shyr, Chien An Liu

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Purpose: To evaluate the clinical outcomes of preventive covered stent placement at the gastroduodenal artery stump in patients with angiogram-negative sentinel hemorrhage after pancreaticoduodenectomy. Methods: Between July 2006 and September 2018, patients undergoing computed tomography angiography or diagnostic angiography for sentinel hemorrhage after pancreaticoduodenectomy were retrospectively reviewed. Patients having angiogram-negative angiography and undergoing preventive covered stent placement or conservative treatment were included. Clinical outcomes, technique success, and complications were evaluated. Results: A total of 25 patients (mean age 62.5 years) were evaluated, including 15 patients underwent preventive covered stent placement at the gastroduodenal artery stump and 10 patients received conservative treatments. The clinical success rates were 50% (5/10) and 86.7% (13/15) for conservative treatments and covered stent groups, respectively (p = 0.07). In the conservative treatment group, delayed massive hemorrhage occurred in five patients, two of whom died of recurrent bleeding due to gastroduodenal artery pseudoaneurysm within 16 days, and two had intraluminal hemorrhage within 5 days. In the covered stent group, one patient had inferior pancreaticoduodenal artery pseudoaneurysm 1 day after the placement of the covered stent, and one had recurrent bleeding due to duodenal ulcer within 14 days. The 30-day mortality was 40% (4/10) and 0 in the conservative treatment and covered stent groups, respectively (p = 0.02). The difference in the overall survival was nonsignificant between the two groups (p = 0.23). Conclusions: The preventive covered stent placement at the gastroduodenal artery stump is safe and reduces delayed massive hemorrhage and short-term mortality in patients with angiogram-negative sentinel hemorrhage after pancreaticoduodenectomy. Graphic Abstract: [Figure not available: see fulltext.].

Original languageEnglish (US)
Pages (from-to)4995-5006
Number of pages12
JournalAbdominal Radiology
Volume46
Issue number10
DOIs
StatePublished - Oct 2021

Keywords

  • Endovascular procedures
  • Hemorrhage
  • Pancreaticoduodenectomy
  • Stents

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging
  • Gastroenterology
  • Urology

Fingerprint

Dive into the research topics of 'Preventive covered stent placement at the gastroduodenal artery stump in angiogram-negative sentinel hemorrhage after pancreaticoduodenectomy'. Together they form a unique fingerprint.

Cite this