T1 - Quantification of brown adipose tissue in vivo using synthetic magnetic resonance imaging
T2 - An experimental study with mice model
AU - Huo, Mengjuan
AU - Ye, Junzhao
AU - Dong, Zhi
AU - Cai, Huasong
AU - Wang, Meng
AU - Yin, Guoping
AU - Qian, Long
AU - Li, Zi Ping
AU - Zhong, Bihui
AU - Feng, Shi Ting
N1 - Publisher Copyright:
© Quantitative Imaging in Medicine and Surgery. All rights reserved.
PY - 2022/1
Y1 - 2022/1
N2 - Background: The white adipose tissue (WAT) and brown adipose tissue (BAT) are associated with the development of several obesity-associated disorders. The use of imaging techniques to differentiate BAT from WAT and quantify BAT volume remains challenging, due to limitations such as spatial resolution and magnetic field inhomogeneity. This study aimed to investigate the feasibility for differentiating BAT from WAT, and quantify the BAT volume in vivo using synthetic magnetic resonance imaging (MRI). Methods: A total of 16 C57BL/6 mice were scanned using synthetic MRI. Quantitative longitudinal relaxation time (T1) and transverse relaxation time (T2) maps were obtained from the original synthetic MRI data using the synthetic MRI software offline. The T1 and T2 values of interscapular BAT (IBAT) and dorsal subcutaneous WAT were measured. The IBAT volume was calculated using synthetic MRI-derived T2-weighted images (T2WIs) based on its morphological characteristics and quantitative tissue values. The body weight of mice was measured, and the IBAT specimens were excised and weighted. The correlation between IBAT volume and the weight of IBAT gross specimen and between IBAT volume and mouse body weight was analyzed. Results: The T1 values of BAT (330.3±19.57 ms) were higher than those of WAT (304.42±4.14 ms) (P<0.001), whereas the T2 values of BAT (66.06±5.06 ms) were lower than those of WAT (88.23±7.68 ms) (P<0.001). The area under the curve (AUC) values of the T1 and T2 for differentiating BAT from WAT was 0.942 and 0.995, respectively. The AUC of the T2 values was higher than that of T1 (P=0.04) using the DeLong test. The optimal cut-off value for T2 was 76 ms for differentiating BAT from WAT (100% sensitivity, 93.7% specificity). A moderate correlation was observed between IBAT volume and the weight of the IBAT gross specimen (r=0.662, P=0.014), and between IBAT volume and mouse body weight (r=0.653, P=0.016). Conclusions: The quantitative parameters derived using synthetic MRI may be used to detect and differentiate BAT from WAT in vivo. Synthetic MRI may help quantify BAT volume in vivo.
AB - Background: The white adipose tissue (WAT) and brown adipose tissue (BAT) are associated with the development of several obesity-associated disorders. The use of imaging techniques to differentiate BAT from WAT and quantify BAT volume remains challenging, due to limitations such as spatial resolution and magnetic field inhomogeneity. This study aimed to investigate the feasibility for differentiating BAT from WAT, and quantify the BAT volume in vivo using synthetic magnetic resonance imaging (MRI). Methods: A total of 16 C57BL/6 mice were scanned using synthetic MRI. Quantitative longitudinal relaxation time (T1) and transverse relaxation time (T2) maps were obtained from the original synthetic MRI data using the synthetic MRI software offline. The T1 and T2 values of interscapular BAT (IBAT) and dorsal subcutaneous WAT were measured. The IBAT volume was calculated using synthetic MRI-derived T2-weighted images (T2WIs) based on its morphological characteristics and quantitative tissue values. The body weight of mice was measured, and the IBAT specimens were excised and weighted. The correlation between IBAT volume and the weight of IBAT gross specimen and between IBAT volume and mouse body weight was analyzed. Results: The T1 values of BAT (330.3±19.57 ms) were higher than those of WAT (304.42±4.14 ms) (P<0.001), whereas the T2 values of BAT (66.06±5.06 ms) were lower than those of WAT (88.23±7.68 ms) (P<0.001). The area under the curve (AUC) values of the T1 and T2 for differentiating BAT from WAT was 0.942 and 0.995, respectively. The AUC of the T2 values was higher than that of T1 (P=0.04) using the DeLong test. The optimal cut-off value for T2 was 76 ms for differentiating BAT from WAT (100% sensitivity, 93.7% specificity). A moderate correlation was observed between IBAT volume and the weight of the IBAT gross specimen (r=0.662, P=0.014), and between IBAT volume and mouse body weight (r=0.653, P=0.016). Conclusions: The quantitative parameters derived using synthetic MRI may be used to detect and differentiate BAT from WAT in vivo. Synthetic MRI may help quantify BAT volume in vivo.
KW - Brown adipose tissue (BAT)
KW - Longitudinal relaxation time (T1)
KW - Synthetic magnetic resonance imaging (MRI)
KW - Transverse relaxation time (T2)
KW - White adipose tissue (WAT)
UR - http://www.scopus.com/inward/record.url?scp=85119095440&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85119095440&partnerID=8YFLogxK
U2 - 10.21037/qims-20-1344
DO - 10.21037/qims-20-1344
M3 - Article
C2 - 34993098
AN - SCOPUS:85119095440
SN - 2223-4292
VL - 12
SP - 526
EP - 538
JO - Quantitative Imaging in Medicine and Surgery
JF - Quantitative Imaging in Medicine and Surgery
IS - 1
ER -