Quantitative Assessment of Breast Cosmetic Outcome After Whole-Breast Irradiation

Jay P. Reddy, Xiudong Lei, Sheng Cheng Huang, Krista M. Nicklaus, Michelle C. Fingeret, Simona F. Shaitelman, Kelly K. Hunt, Thomas A. Buchholz, Fatima Merchant, Mia K. Markey, Benjamin D. Smith

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

Purpose To measure, by quantitative analysis of digital photographs, breast cosmetic outcome within the setting of a randomized trial of conventionally fractionated (CF) and hypofractionated (HF) whole-breast irradiation (WBI), to identify how quantitative cosmesis metrics were associated with patient- and physician-reported cosmesis and whether they differed by treatment arm. Methods and Materials From 2011 to 2014, 287 women aged ≥40 with ductal carcinoma in situ or early invasive breast cancer were randomized to HF-WBI (42.56 Gy/16 fractions [fx] + 10-12.5 Gy/4-5 fx boost) or CF-WBI (50 Gy/25 fx + 10-14 Gy/5-7 fx). At 1 year after treatment we collected digital photographs, patient-reported cosmesis using the Breast Cancer Treatment and Outcomes Scale, and physician-reported cosmesis using the Radiation Therapy Oncology Group scale. Six quantitative measures of breast symmetry, labeled M1-M6, were calculated from anteroposterior digital photographs. For each measure, values closer to 1 imply greater symmetry, and values closer to 0 imply greater asymmetry. Associations between M1-M6 and patient- and physician-reported cosmesis and treatment arm were evaluated using the Kruskal-Wallis test. Results Among 245 evaluable patients, patient-reported cosmesis was strongly associated with M1 (vertical symmetry measure) (P<.01). Physician-reported cosmesis was similarly correlated with M1 (P<.01) and also with M2 (vertical symmetry, P=.01) and M4 (horizontal symmetry, P=.03). At 1 year after treatment, HF-WBI resulted in better values of M2 (P=.02) and M3 (P<.01) than CF-WBI; treatment arm was not significantly associated with M1, M4, M5, or M6 (P≥.12). Conclusions Quantitative assessment of breast photographs reveals similar to improved cosmetic outcome with HF-WBI compared with CF-WBI 1 year after treatment. Assessing cosmetic outcome using these measures could be useful for future comparative effectiveness studies and outcome reporting.

Original languageEnglish (US)
Pages (from-to)894-902
Number of pages9
JournalInternational Journal of Radiation Oncology Biology Physics
Volume97
Issue number5
DOIs
StatePublished - Apr 1 2017

ASJC Scopus subject areas

  • Radiation
  • Oncology
  • Radiology Nuclear Medicine and imaging
  • Cancer Research

MD Anderson CCSG core facilities

  • Assessment, Intervention, and Measurement

Fingerprint

Dive into the research topics of 'Quantitative Assessment of Breast Cosmetic Outcome After Whole-Breast Irradiation'. Together they form a unique fingerprint.

Cite this