Reference dosimetry data and modeling challenges for Elekta accelerators based on IROC-Houston site visit data

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

Purpose: Reference dosimetry data can provide an independent second check of acquired values when commissioning or validating a treatment planning system (TPS). The Imaging and Radiation Oncology Core at Houston (IROC-Houston) has measured numerous linear accelerators throughout its existence. The results of those measurements are given here, comparing accelerators and the agreement of measurement versus institutional TPS calculations. Methods: Data from IROC-Houston on-site reviews from 2000 through 2014 were analyzed for all Elekta accelerators, approximately 50. For each, consistent point dose measurements were conducted for several basic parameters in a water phantom, including percentage depth dose, output factors, small-field output factors, off-axis factors, and wedge factors. The results were compared by accelerator type independently for 6, 10, 15, and 18 MV. Distributions of the measurements for each parameter are given, providing the mean and standard deviation. Each accelerator's measurements were also compared to its corresponding TPS calculation from the institution to determine the level of agreement, as well as determining which dosimetric parameters were most often in error. Results: Accelerators were grouped by head type and reference dosimetric values were compiled. No class of linac had better overall agreement with its TPS, but percentage depth dose and output factors commonly agreed well, while small-field output factors, off-axis factors, and wedge factors often disagreed substantially from their TPS calculations. Conclusion: Reference data has been collected and analyzed for numerous Elekta linacs, which provide an independent way for a physicist to double-check their own measurements to prevent gross treatment errors. In addition, treatment planning parameters more often in error have been highlighted, providing practical caution for physicists commissioning treatment planning systems for Elekta linacs.

Original languageEnglish (US)
Pages (from-to)2337-2344
Number of pages8
JournalMedical physics
Volume45
Issue number5
DOIs
StatePublished - May 2018

Keywords

  • IROC-Houston
  • linac
  • percentage depth dose
  • reference data
  • small field

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Reference dosimetry data and modeling challenges for Elekta accelerators based on IROC-Houston site visit data'. Together they form a unique fingerprint.

Cite this