T1 - Restarted primal-dual Newton conjugate gradient method for enhanced spatial resolution of reconstructed cone-beam X-ray luminescence computed tomography images
AU - Gao, Peng
AU - Cheng, Kai
AU - Schüler, Emil
AU - Jia, Mengyu
AU - Zhao, Wei
AU - Xing, Lei
N1 - Publisher Copyright:
© 2020 Institute of Physics and Engineering in Medicine.
PY - 2020/7/7
Y1 - 2020/7/7
N2 - Cone-beam X-ray luminescence computed tomography (CB-XLCT) has been proposed as a promising imaging tool, which enables three-dimensional imaging of the distribution of nanophosphors (NPs) in small animals. However, the reconstruction performance is usually unsatisfactory in terms of spatial resolution due to the ill-posedness of the CB-XLCT inverse problem. To alleviate this problem and to achieve high spatial resolution, a reconstruction method consisting of inner and outer iterations based on a restarted strategy is proposed. In this method, the primal-dual Newton conjugate gradient method (pdNCG) is adopted in the inner iterations to get fast reconstruction, which is used for resetting the permission region and increasing the convergence speed of the outer iteration. To assess the performance of the method, both numerical simulation and physical phantom experiments were conducted with a CB-XLCT system. The results demonstrate that compared with conventional reconstruction methods, the proposed re-pdNCG method can accurately and efficiently resolve the adjacent NPs with the least relative error.
AB - Cone-beam X-ray luminescence computed tomography (CB-XLCT) has been proposed as a promising imaging tool, which enables three-dimensional imaging of the distribution of nanophosphors (NPs) in small animals. However, the reconstruction performance is usually unsatisfactory in terms of spatial resolution due to the ill-posedness of the CB-XLCT inverse problem. To alleviate this problem and to achieve high spatial resolution, a reconstruction method consisting of inner and outer iterations based on a restarted strategy is proposed. In this method, the primal-dual Newton conjugate gradient method (pdNCG) is adopted in the inner iterations to get fast reconstruction, which is used for resetting the permission region and increasing the convergence speed of the outer iteration. To assess the performance of the method, both numerical simulation and physical phantom experiments were conducted with a CB-XLCT system. The results demonstrate that compared with conventional reconstruction methods, the proposed re-pdNCG method can accurately and efficiently resolve the adjacent NPs with the least relative error.
KW - X-ray luminescence computed tomography
KW - ill-posed
KW - reconstruction techniques
UR - http://www.scopus.com/inward/record.url?scp=85088043132&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85088043132&partnerID=8YFLogxK
U2 - 10.1088/1361-6560/ab87fb
DO - 10.1088/1361-6560/ab87fb
M3 - Article
C2 - 32268318
AN - SCOPUS:85088043132
SN - 0031-9155
VL - 65
JO - Physics in medicine and biology
JF - Physics in medicine and biology
IS - 13
M1 - 135008
ER -