T1 - Spontaneous migration to a higher dose in computed radiography (CR) imaging
AU - Gur, David
AU - Fuhrman, Carl R.M.D.
AU - Feist, John H.
AU - Slifko, Robert
AU - Peace, Barbara
AU - Shaw, Chris C.
PY - 1995
Y1 - 1995
N2 - In order to subjectively determine acceptable dose levels for portable CR, two blind experiments were performed while maintaining conventional screen-film radiography as a reference quality. In the first experiment, a team of two technologists and two radiologists were trained to expose and to quality-assure portable CR images obtained with standard screens at conventional exposures (400 speed). After providing them with a new set of cassettes and informing them that these were 'better and faster,: they were allowed to practice clinically, using the system for bedside AP chest radiography. After four weeks, exposure factors used in those cases were reviewed, and the experiment was repeated with two different teams and two CR systems. In the second experiment, portable CR was used for a large number of cases. The number of radiologists who complained about CR image quality was monitored for cased were alternating technologies (CR and conventional) were used and routinely viewed side by side. during a two-month period, radiation dose gradually increased to a level where radiologists' complaints were significantly reduced. In both experiments, exposure levels gradually migrated to and stabilized at 40-60% higher levels than that routinely used with conventional 400-speed film screen techniques. The perceived need for high exposure ratios between Cr and conventional radiography was related to body size. When the reference quality 'gold standard' remains unchanged, Cr requires higher exposures to yield acceptable image quality, particularly in large patients.
AB - In order to subjectively determine acceptable dose levels for portable CR, two blind experiments were performed while maintaining conventional screen-film radiography as a reference quality. In the first experiment, a team of two technologists and two radiologists were trained to expose and to quality-assure portable CR images obtained with standard screens at conventional exposures (400 speed). After providing them with a new set of cassettes and informing them that these were 'better and faster,: they were allowed to practice clinically, using the system for bedside AP chest radiography. After four weeks, exposure factors used in those cases were reviewed, and the experiment was repeated with two different teams and two CR systems. In the second experiment, portable CR was used for a large number of cases. The number of radiologists who complained about CR image quality was monitored for cased were alternating technologies (CR and conventional) were used and routinely viewed side by side. during a two-month period, radiation dose gradually increased to a level where radiologists' complaints were significantly reduced. In both experiments, exposure levels gradually migrated to and stabilized at 40-60% higher levels than that routinely used with conventional 400-speed film screen techniques. The perceived need for high exposure ratios between Cr and conventional radiography was related to body size. When the reference quality 'gold standard' remains unchanged, Cr requires higher exposures to yield acceptable image quality, particularly in large patients.
UR - http://www.scopus.com/inward/record.url?scp=0029453197&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029453197&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:0029453197
SN - 081941784X
SN - 9780819417848
T3 - Proceedings of SPIE - The International Society for Optical Engineering
SP - 70
EP - 73
BT - Proceedings of SPIE - The International Society for Optical Engineering
A2 - Kundel, Harold L.
T2 - Medical Imaging 1995: Image Perception
Y2 - 1 March 1995 through 1 March 1995
ER -