Statistical Shape Model to Generate a Planning Library for Cervical Adaptive Radiotherapy

Bastien Rigaud, Antoine Simon, Maxime Gobeli, Julie Leseur, Loig Duvergé, Danièle Williaume, Joël Castelli, Caroline Lafond, Oscar Acosta, Pascal Haigron, Renaud De Crevoisier

Research output: Contribution to journalArticlepeer-review

33 Scopus citations

Abstract

External beam radiotherapy is extensively used to treat cervical carcinomas. A single planning CT scan enables the calculation of the dose distribution. The treatment is delivered over five weeks. Large per-treatment anatomical variations may hamper the dose delivery, with the potential of an organ-at-risk (OAR) overdose and a tumor underdose. To anticipate these deformations, a recent approach proposed three planning CTs with variable bladder volumes, which had the limitation of not covering all per-treatment anatomical variations. An original patient-specific population-based library has been proposed. It consisted of generating two representative anatomies, in addition to the standard planning CT anatomy. First, the cervix and bladder meshes of a population of 20 patients (314 images) were registered to an anatomical template, using a deformable mesh registration. An iterative point-matching algorithm was developed based on local shape context (histogram of polar or cylindrical coordinates and geodesic distance to the base) and on a topology constraint filter. Second, a standard principal component analysis (PCA) model of the cervix and bladder was generated to extract the dominant deformation modes. Finally, specific deformations were obtained using posterior PCA models, with a constraint representing the top of the uterus deformation. For a new patient, the cervix-uterus and bladder were registered to the template, and the patient's modeled planning library was built according to the model deformations. This method was applied following a leave-one-patient-out cross-validation. The performances of the modeled library were compared to those of the three-CT-based library, showing an improvement in both target coverage and OAR sparing.

Original languageEnglish (US)
Article number8438508
Pages (from-to)406-416
Number of pages11
JournalIEEE Transactions on Medical Imaging
Volume38
Issue number2
DOIs
StatePublished - Feb 2019

Keywords

  • PCA model
  • Radiotherapy
  • cervical
  • deformable mesh registration
  • planning library

ASJC Scopus subject areas

  • Software
  • Radiological and Ultrasound Technology
  • Computer Science Applications
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Statistical Shape Model to Generate a Planning Library for Cervical Adaptive Radiotherapy'. Together they form a unique fingerprint.

Cite this