SU‐E‐T‐410: Spine Radiosurgery Imaging Guidance Using ExacTrac and CT on rails

J. Yang, X. Wang, Z. Zhao, P. Brown

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

Purpose: To evaluate the patient setup accuracy and effectiveness using ExacTrac and CT_on_rails systems. Methods: We used Brainlab's Exactrac system and Varian/GE's CT_on_rails for spine radiosurgery patient setup. Once the patient was setup using the ExacTrac and couch position was recorded, fiducially markers were placed on stable surfaces based on the room laser to indicate the linac iso for the CT images. CT images were acquired using the on‐rail CT with the couch rotated 180 degrees. The couch was returned to 0 degree position, and verification X‐ray images were taken and corrections were made by ExacTrac. The treatment CT images were registered with the planning CT using the in‐house CAT software and it displays the correct couch position based on CT which can be compared with ExacTrac setup. The corrected couch positions from CT registration are compared to those from ExacTrac. The translational discrepancies needed to be within 2 mm for confirmation. If a discrepancy was greater than 2 mm, investigation or re‐setup was required. The rotation deviations were also evaluated by ExacTrac and confirmed by the treatment CT images. We would also re‐setup patient if Exactrac detected more than 3 degree rotation, or treatment CT images showed significant target rotation compared to planning CT. The use of the CTonrails took little extra time, but make the overall evaluation process easier, faster and with more confidence. Results: for 171 treatment sessions using this approach, the mean discrepancies between CTonrails and ExacTrac setup is: x=0.0±1.0 mm, y=−0. 1±0.9 mm, z=0.2±0.9 mm; for rotations, about 3% of the cases required re‐setup patient due to significant rotation displayed by the treatment CT on the CAT system. Conclusions: The combined use of ExacTrac and CT_on_Rails systems can improve the overall setup accuracy and increase the confidence in setup for spine radiosurgery treatments.

Original languageEnglish (US)
Pages (from-to)3799
Number of pages1
JournalMedical physics
Volume39
Issue number6
DOIs
StatePublished - Jun 2012

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'SU‐E‐T‐410: Spine Radiosurgery Imaging Guidance Using ExacTrac and CT on rails'. Together they form a unique fingerprint.

Cite this