SU‐E‐T‐62: Modeling Influence Factors of Al2O3:C Optically Stimulated Luminescence Detectors (OSLDs) Exposed to Radiotherapy Beams

G. O. Sawakuchi, A. Omotayo, E. G. Yukihara

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Purpose: The optically stimulated luminescence (OSL) technique is becoming increasingly popular in medical dosimetry. This is partially because of the dosimetric properties of Al2O3:C, the most common commercially available OSL detector (OSLD). Currently, there is no reference dosimetry protocol based on measurements using Al2O3:C OSLDs in radiotherapy beams. Influence factors, if not properly accountedfor, may introduce large systematic uncertainties in the dose measurements.In this work we develop a phenomenological model based on band structure theory that can be used to investigated the role of different influence factors on the OSL response of Al2O3:C OSLDs exposed to photon beams. Methods: To describe the charge transportation processes that lead to the OSL response of Al2O3:C OSLDs, we used a band diagram model consisting of three electron traps (shallow, main and deep traps) and two luminescence recombination centers. Based on this model we established a system of differential equations that represent the transport of charge carriers (electrons and holes) during irradiation, relaxation and stimulation of the material. Then we solved this system of differential equations todetermine the role of factors that may influence the OSL response including: irradiation temperature, time elapsed since irradiation (fading), non‐linearityof the dose response, accumulated dose and resetting or bleaching method. Results: The OSL signal: 1) depends on irradiation temperature in the temperature range relevant to medical dosimetry (15 to 40°C); 2) fades as a function of time elapsed since irradiation. The fading is dose dependent; 3) has a non‐linear dose‐response, which depends on the detected OSL emission; and 4) changes as a function of accumulated dose and resetting method. Conclusion: The proposed band diagram model may be used tounderstand the role of influence factors on Al2O3:C OSLDs, which willhelp in the development of reference dosimetry protocols based on measurements using Al2O3:C OSLDs. Natural Sciences and Engineering Research Council of Canada.

Original languageEnglish (US)
Pages (from-to)3716
Number of pages1
JournalMedical physics
Volume39
Issue number6
DOIs
StatePublished - Jun 2012
Externally publishedYes

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'SU‐E‐T‐62: Modeling Influence Factors of Al2O3:C Optically Stimulated Luminescence Detectors (OSLDs) Exposed to Radiotherapy Beams'. Together they form a unique fingerprint.

Cite this