SU‐GG‐T‐463: Study of the Magnitude of Detector Size Effect in the Measured Lateral Profiles of Proton Pencil Beam Spots

N. Sahoo, G. Ciangaru, G. Sawakuchi, A. Anand, F. Poenisch, K. Suzuki, R. Mohan, M. Gillin, X. Zhu

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Purpose: Lateral profiles of therapeutic radiation beams measured by ionization chambers are known to be affected by their sizes. The purpose of this study is to quantify the detector size effect on the measurements of lateral profiles of the proton pencil beam spots (PPBS) of the scanning beam nozzle of the Proton Therapy Center at Houston. Methods and Materials: In‐air and in‐water lateral profiles of 72.5, 163.9 and 221.8 MeV energy PPBS were measured by a PTW 31014 Pinpoint ionization chamber (IC) (radius of 0.1 cm). The measured profiles were fitted to a sum of multiple Gaussians and were deconvolved with a Gaussian detector response kernel, K(x) = A. exp (‐ x2/2σκ2) with σκ taken as the radius of the IC. The deconvolved profiles are also given by the sum of Gaussians with modified σ2 = σm 2 ‐ σκ2, where σm is the sigma of a Gaussian in the fitted measured profiles. The full width at half maxima (FWHM) and full width at 0.9 and 0.01 of the maxima, (FW0.9M, FW0.01M) of the profiles with and without the detector size corrections were compared to quantify the effect of the IC size on the in‐air and inwater lateral profiles of PPBS. Results: The maximum differences between the uncorrected and corrected FWHM, FW0.9M and FW0.01M for the PPBS of all the three energies in this study, were found to be less than 0.3, 0.1, 0.5 mm for in‐air and 0.2, 0.1, 0.3 mm for in‐water lateral profiles respectively. The detector size corrected and the measured lateral profiles were found to be very close to each other. Conclusion: The analytical deconvolution method with a Gaussian detector response kernel indicates that the detector size has a rather small effect on the Gaussian like lateral profiles of PPBS measured with small ionization chambers.

Original languageEnglish (US)
Pages (from-to)3293
Number of pages1
JournalMedical physics
Volume37
Issue number6
DOIs
StatePublished - Jun 2010

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'SU‐GG‐T‐463: Study of the Magnitude of Detector Size Effect in the Measured Lateral Profiles of Proton Pencil Beam Spots'. Together they form a unique fingerprint.

Cite this