TY - JOUR
T1 - Systematic review with meta-analysis
T2 - Magnetic resonance enterography vs. computed tomography enterography for evaluating disease activity in small bowel Crohn's disease
AU - Qiu, Y.
AU - Mao, R.
AU - Chen, B. L.
AU - Li, X. H.
AU - He, Y.
AU - Zeng, Z. R.
AU - Li, Z. P.
AU - Chen, M. H.
PY - 2014/7
Y1 - 2014/7
N2 - Background Magnetic resonance enterography (MRE) has been proposed as a non-ionising alternative method to computed tomography enterography (CTE). Some studies have directly compared CTE and MRE in patients with small bowel Crohn's disease (CD) with variable results. Aim To compare the overall diagnostic accuracy in assessing the activity of small bowel and complications. Methods MEDLINE, EMBASE and Cochrane databases were searched for studies on the accuracy of MRE and CTE, as compared with a pre-defined reference standard. Pooled sensitivity, specificity, the weighted area under the curve (AUC), incremental yield (IY) and other diagnostic indices were evaluated. Results A total of 290 CD patients from six different studies were analysed. The pooled sensitivity and specificity for MRE in detecting active small bowel CD was 87.9% [95% confidence interval (CI), 81.8-92.5] and 81.2% (95% CI: 71.9-88.4) respectively. The AUC under the summary receiver-operating characteristic (sROC) of MRE was 0.905 (SEM 0.03, standard error of the mean). Likewise, the pooled sensitivity and specificity of CTE in detecting active small bowel CD was 85.8% (95% CI: 79.2-90.9) and 83.6% (95% CI: 75.3-90.1) with the AUC of 0.898. The AUC of MRE in detecting fistula, stenosis and abscess was 0.936, 0.931 and 0.996, respectively, compared to 0.963, 0.616 and 0.899 of CTE. No statistically significant IY for MRE vs. CTE was found (fixed model, P > 0.05). Conclusions Magnetic resonance enterography has a diagnostic effectiveness comparable to computed tomography enterography, thus may serve as a radiation-free alternative for evaluation of patients with Crohn's disease.
AB - Background Magnetic resonance enterography (MRE) has been proposed as a non-ionising alternative method to computed tomography enterography (CTE). Some studies have directly compared CTE and MRE in patients with small bowel Crohn's disease (CD) with variable results. Aim To compare the overall diagnostic accuracy in assessing the activity of small bowel and complications. Methods MEDLINE, EMBASE and Cochrane databases were searched for studies on the accuracy of MRE and CTE, as compared with a pre-defined reference standard. Pooled sensitivity, specificity, the weighted area under the curve (AUC), incremental yield (IY) and other diagnostic indices were evaluated. Results A total of 290 CD patients from six different studies were analysed. The pooled sensitivity and specificity for MRE in detecting active small bowel CD was 87.9% [95% confidence interval (CI), 81.8-92.5] and 81.2% (95% CI: 71.9-88.4) respectively. The AUC under the summary receiver-operating characteristic (sROC) of MRE was 0.905 (SEM 0.03, standard error of the mean). Likewise, the pooled sensitivity and specificity of CTE in detecting active small bowel CD was 85.8% (95% CI: 79.2-90.9) and 83.6% (95% CI: 75.3-90.1) with the AUC of 0.898. The AUC of MRE in detecting fistula, stenosis and abscess was 0.936, 0.931 and 0.996, respectively, compared to 0.963, 0.616 and 0.899 of CTE. No statistically significant IY for MRE vs. CTE was found (fixed model, P > 0.05). Conclusions Magnetic resonance enterography has a diagnostic effectiveness comparable to computed tomography enterography, thus may serve as a radiation-free alternative for evaluation of patients with Crohn's disease.
UR - http://www.scopus.com/inward/record.url?scp=84902854033&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84902854033&partnerID=8YFLogxK
U2 - 10.1111/apt.12815
DO - 10.1111/apt.12815
M3 - Review article
C2 - 24912799
AN - SCOPUS:84902854033
SN - 0269-2813
VL - 40
SP - 134
EP - 146
JO - Alimentary Pharmacology and Therapeutics
JF - Alimentary Pharmacology and Therapeutics
IS - 2