T2 - Experimental Study of Neutron Dose Equivalent in a Proton Treatment Facility
AU - Wang, X.
AU - Gillin, M.
PY - 2008/6
Y1 - 2008/6
N2 - Purpose: To characterize neutron dose equivalent per proton Gray (H/D) as a function of proton energy, spread‐out Bragg peak (SOBP) and aperture size at a clinical proton treatment facility using both active and passive neutron detection instruments, and to evaluate the performance of the instruments for a possible candidate for routine patient neutron exposure monitoring. Method and Materials: The H/D were measured at 2 locations near isocenter, namely in proton field but 2 cm out of range and approximately 20 cm out of field, with neutron instruments of various types. Two types of rem‐meters were used, the REM‐500, a tissue equivalent proportional counter and SWENDI‐2, a wide energy (up to 5GeV) neutron probe. The passive detectors consist of Neutrak® 144 Fast, Intermediate and Thermal Neutron Dosimeters, an etched‐track detector, and two flavors of bubble detector, BDS®, a spectrometer, and BD‐PND®. The results from these instruments were compared for 200 MeV and 160 MeV beam configurations. REM‐500 and Neutrak® were used to study the dependency of H/D on proton energy, SOBP and aperture size. Results: Various instruments had comparable H/D measurements at the out field location but varies more at the in field location. The H/D value increased linearly with proton energy, with a factor of ∼6 from 100 MeV to 250 MeV for medium snout. The H/D value increased ∼50% with increasing SOBP from 2 cm to the maximum of clinical allowed value and had a small decrease with aperture size. Conclusion: The measured results show H/D increases strongly with proton energy, moderately with SOBP, and has minimal dependence on aperture size. This is consistent with the simulation results. The Neutrak® etched‐track detector is a good candidate for patient neutron exposure monitoring due to its small size, excellent dose range, good energy range and commercial support.
AB - Purpose: To characterize neutron dose equivalent per proton Gray (H/D) as a function of proton energy, spread‐out Bragg peak (SOBP) and aperture size at a clinical proton treatment facility using both active and passive neutron detection instruments, and to evaluate the performance of the instruments for a possible candidate for routine patient neutron exposure monitoring. Method and Materials: The H/D were measured at 2 locations near isocenter, namely in proton field but 2 cm out of range and approximately 20 cm out of field, with neutron instruments of various types. Two types of rem‐meters were used, the REM‐500, a tissue equivalent proportional counter and SWENDI‐2, a wide energy (up to 5GeV) neutron probe. The passive detectors consist of Neutrak® 144 Fast, Intermediate and Thermal Neutron Dosimeters, an etched‐track detector, and two flavors of bubble detector, BDS®, a spectrometer, and BD‐PND®. The results from these instruments were compared for 200 MeV and 160 MeV beam configurations. REM‐500 and Neutrak® were used to study the dependency of H/D on proton energy, SOBP and aperture size. Results: Various instruments had comparable H/D measurements at the out field location but varies more at the in field location. The H/D value increased linearly with proton energy, with a factor of ∼6 from 100 MeV to 250 MeV for medium snout. The H/D value increased ∼50% with increasing SOBP from 2 cm to the maximum of clinical allowed value and had a small decrease with aperture size. Conclusion: The measured results show H/D increases strongly with proton energy, moderately with SOBP, and has minimal dependence on aperture size. This is consistent with the simulation results. The Neutrak® etched‐track detector is a good candidate for patient neutron exposure monitoring due to its small size, excellent dose range, good energy range and commercial support.
UR - http://www.scopus.com/inward/record.url?scp=85024774388&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85024774388&partnerID=8YFLogxK
U2 - 10.1118/1.2962897
DO - 10.1118/1.2962897
M3 - Article
AN - SCOPUS:85024774388
SN - 0094-2405
VL - 35
SP - 2982
EP - 2983
JO - Medical physics
JF - Medical physics
IS - 6
ER -