The effects of compensator design on scatter distribution and magnitude: A Monte Carlo study

G. J. Bootsma, F. Verhaegen, D. A. Jaffray

Research output: Chapter in Book/Report/Conference proceedingConference contribution

6 Scopus citations

Abstract

X-ray scatter has a significant impact on image quality in kV cone-beam CT (CBCT), its effects include: CT number inaccuracy, streak and cupping artifacts, and loss of contrast. Compensators provide a method for not only decreasing the magnitude of the scatter distribution, but also reducing the structure found in the scatter distribution. Recent Monte Carlo (MC) simulations examining X-ray scatter in CBCT projection images have shown that the scatter distribution in x-ray imaging contains structure largely induced by coherent scattering. In order to maximize the reduction of x-ray scatter induced artifacts a decrease in the magnitude and structure of the scatter distribution is sought through optimal compensator design. A flexible MC model that allows for separation of scattered and primary photons has been created to simulate the CBCT imaging process. The CBCT MC model is used to investigate the effectiveness of compensators in decreasing the magnitude and structure of the scatter distribution in CBCT projection images. The influence of the compensator designs on the scatter distribution are evaluated for different anatomy (abdomen, pelvis, and head and neck) and viewing angles using a voxelized anthropomorphic phantom. The effect of compensator material composition on the amount of contamination photons in an open field is also investigated.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2011
Subtitle of host publicationPhysics of Medical Imaging
DOIs
StatePublished - 2011
Externally publishedYes
EventMedical Imaging 2011: Physics of Medical Imaging - Lake Buena Vista, FL, United States
Duration: Feb 13 2011Feb 17 2011

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume7961
ISSN (Print)1605-7422

Other

OtherMedical Imaging 2011: Physics of Medical Imaging
Country/TerritoryUnited States
CityLake Buena Vista, FL
Period2/13/112/17/11

Keywords

  • Cone-Beam CT
  • Monte Carlo
  • X-ray scatter
  • bowtic
  • compensator
  • image quality

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'The effects of compensator design on scatter distribution and magnitude: A Monte Carlo study'. Together they form a unique fingerprint.

Cite this