Compatibility of ondansetron hydrochloride with meperidine hydrochloride for combined administration

Q. A. Xu, L. A. Trissel, J. L. Fox

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

OBJECTIVE: To determine the physical compatibility and chemical stability of ondansetron hydrochloride 0.1 and 1 mg/mL with meperidine hydrochloride 4 mg/mL admixed in NaCl 0.9% injection USP. DESIGN: Triplicate test solutions of the drags in NaCl 0.9% injection USP were prepared and stored at 4, 22, and 32 °C. Samples were removed initially and at various time points over 31 days and were stored at -70 °C until they were analyzed. Physical compatibility was assessed by measuring solution turbidity with a color- correcting turbidimeter and particle content with a light-obscuration particle sizer/counter, as well as by visual assessment. Chemical stability of the drags was determined using a stability-indicating HPLC analytic method. Duplicate determinations were performed on each sample to measure the concentration of each drug. RESULTS: All admixtures were found to exhibit no visual or subvisual changes of consequence in turbidity or particle content at all observation points. Further, little or no loss of any of the drugs occurred in any concentration throughout the study. CONCLUSIONS: The physical compatibility and chemical stability of ondansetron hydrochloride with meperidine hydrochloride under the conditions of this study have been established for 7 days at 32 °C and 31 days at 4 and 22 °C.

Original languageEnglish (US)
Pages (from-to)1106-1109
Number of pages4
JournalAnnals of Pharmacotherapy
Volume29
Issue number11
DOIs
StatePublished - 1995

ASJC Scopus subject areas

  • Pharmacology (medical)

Fingerprint

Dive into the research topics of 'Compatibility of ondansetron hydrochloride with meperidine hydrochloride for combined administration'. Together they form a unique fingerprint.

Cite this